Product Brochure
Features
• Integral Flow Check (IFC
®
)
Simplifies piping
Prevents reverse flow and gravity flow
Eliminates separate in-line flow check
Reduces installed cost
Improves system performance
Easy to service
• Unique replaceable cartridge-field serviceable
• Unmatched reliability-maintenance free
• Quiet, efficient operation
• Self lubricating, No mechanical seal
• Wide range of applications
• Cast Iron or Stainless Steel construction
• Flanged connections
Materials of Construction
Casing (Volute): Cast Iron or
Stainless Steel
Integral Flow Check (IFC
®
):
Body, Plunger .......Acetal
O-ring Seals ...........EPDM
Spring ........................Stainless Steel
Stator Housing: Steel
Cartridge: Stainless Steel
Impeller: Non-Metallic
Shaft: Ceramic
Bearings: Carbon
O-Ring & Gaskets: EPDM
Model Nomenclature
F – Cast Iron, Flanged
SF – Stainless Steel, Flanged
IFC
®
– Integral Flow Check
Performance Data
Max. Flow: 0 - 17 GPM
Max. Head: 0 - 8.5 Feet
Minimum Fluid Temperature: 40˚F (4˚C)
Maximum Fluid Temperature: 230°F (110˚C)
Maximum Working Pressure: 125 psi
Connection Sizes:
3/4”, 1”, 1-1/4”, 1-1/2”
Flanged
Submittal Data Information
Model 007-IFC
®
Cartridge Circulator
Submittal Data # 101-077
Supersedes: 06/07/10
Effective: 02/25/12
Application
• Hydronic Heating/Cooling • Hydro-Air Fan Coils
• Radiant • Domestic Water Recirculation (Stainless Steel only)
• Indirect Water Heaters
The 007-IFC is designed to simplify piping, reduce installation costs and improve
system performance when zoning with 00
®
circulators. By locating the IFC inside
the pump, a separate in-line flow check is eliminated. The low pressure drop of
the IFC increases flow performance vs. in-line flow checks. Both the IFC and the
cartridge are easily accessed for removal and service.
Performance Field - 60Hz
Mounting Positions
Vertical Horizontal
OK if over
20 psi
Electrical Data
Taco Inc., 1160 Cranston Street. Cranston, RI 02920 / (401) 942-8000 / Fax (401) 942-2360
Taco (Canada) Ltd., 8450 Lawson Road, Unit #3, Milton, Ontario L9T 0J8 / (905) 564-9422 / Fax (905) 564-9436
www.taco-hvac.com
Pump Dimensions & Weights
*Flange Orientation Type
Model Casing
Flange
Type*
A B C D E F
Ship Wt.
in. mm in. mm in. mm in. mm in. mm in. mm lbs. Kg
007-F5-7 IFC Cast Iron S
6-1/8
156 4-1/2 114 3-3/16 81 2-15/16 75 5 127 6-3/8 162 9 4.0
007-F5-8 IFC Cast Iron R
5-7/8
149 4-1/2 114 3-3/16 81 2-15/16 75 5 127 6-3/8 162 9 4.0
007-SF5-7 IFC S. Steel S
6-1/8
156 4-1/2 114 3-3/16 81 2-15/16 75 5 127 6-3/8 162 9 4.0
Standard (S)
Rotated (R)
Model
Volts Hz Ph Amps RPM
HP
Cast Iron
115
60 1 .71 3250 1/25
St. Steel
115
60 1 .76 3250 1/25
Motor
Type
Permanent Split Capacitor
Impedance Protected
Motor
Options
220/50/1, 220/60/1, 230/60/1, 100/110/50/60/1
Low-Lead Compliant
Certifications & Listings
FR IDR uSE Ly