User Instructions

Electrical connection
T12CVS8 HBM: public 43
Do not use cable KAB149 to connect the voltage output signal at AP01i to
ML01B of the MGCplus system!
This cable is only suitable for the frequency output signal connection.
Information
The analog output is designed as a monitoring output. The power transmission
of the torque transducer can cause interference on the connected cable of up
to 40 mV at 13.56 MHz. This interference can be suppressed by the parallel
connection of a 100 nF capacitor, directly at the connected measuring device.
Assignment for plug 4
Standard CAN bus; Acoded, black washer
2
3
Binder 713
(M12x1)
1
4
5
Top view
Plug
pin
Assignment
Color
code
1
Shield
-
2
Not in use
-
3
CAN ground
-
4
CAN HIGH dominant high
wh
5
CAN LOW dominant low
bu
Shield connected to housing ground
Notice