Mechanical installation
T12CVS8 HBM: public 23
Fig. 8.2 Screw connections, flange B
1. Prior to installation, clean the plane faces of the transducer flange and the
counter flange.
For safe torque transfer, the surfaces must be clean and free from grease.
Use a piece of cloth or paper soaked in solvent. When cleaning, make sure
that you do not damage the transmitter coils.
2. For the flange B screw connections, use hexagon socket screws DIN EN
ISO 4762 of property class 12.9 of the appropriate length (depending on
the connection geometry, see Tab. 8.1).
We recommend DIN EN ISO 4762 socket head cap screws, blackened,
smooth-headed, permitted size and shape variance as per DIN ISO 4759,
Part 1, product class A.
3. First tighten all the screws crosswise with 80% of the prescribed tightening
torque (Tab. 8.1), then tighten again crosswise with the full tightening
torque.