Installation Guide
6
General Instructions
IMPORTANT:
· ALL ELECTRICAL WIRING IS TO BE 
INSTALLED IN ACCORDANCE WITH
NATIONAL/LOCAL CODES AND REGULA-
TIONS.
· ALL PLUMBING IS TO BE INSTALLED IN 
ACCORDANCE WITH
APPLICABLE CODES AND REGULATIONS.
· USE APPROPRIATE PRECAUTIONS 
WHILE CONNECTING TRANSFORMER TO 
120 VAC POWER SOURCE.
· DO NOT PLUG TRANSFORMER INTO 
POWER SOURCE (RECEPTACLE) UNTIL 
ALL WIRING IS COMPLETED.
· FLUSH ALL WATER LINES UNTIL WATER 
IS CLEAR BEFORE CONNECTING FAUCET 
TO SUPPLY STOPS.
Tools Required For Installation of 
Faucets
· 8” (200mm) adjustable wrench
· VR Torx wrench (included)
· Basin wrench 
· Slotted screwdriver, 3/16”
· Phillips head screwdriver, #1
· Pliers
Prior to Installation:
Prior to installing the T&S ChekPoint
Series Faucet, install the items listed 
below:
· Scrub or wash-up sink
· Drain line
· Hot and cold water supply lines & 
stops.
(Supply stops must be furnished by 
installer or purchased from T&S.) 
Tighten compression  ttings securely 
on supply lines.
· (OPTIONAL) Provide electrical 
receptacle within approximately 12’ 
from sink for plug-in transformer - 120 
VAC, 2 amp service for each plug-in 
transformer used.
Installation of EC-3130 & EC-3132 
ChekPoint Faucets:
(Refer to Figures 1, 2, 3 and 4)
The EC-3130, EC-3132 & EC-3142 
ChekPoint faucets have above deck 
sensor electronics and temperature 
control. Power is supplied by a 6V 
lithium battery within the faucet 
body. Another power option is an AC 
transformer connected below the deck 
to a lead terminal from the bottom of 
the faucet.
1. Drill a Ø 1 ¼” hole where the faucet 
is to be installed. Maximum deck 
thickness is 1 ½”.
2. Pull the battery saver strip coming 
from the bottom of the faucet. The LED 
light in the sensor lens will light up and 
 icker.
3. If using the AC transformer, connect 
the auxiliary power connector cable to 
the wire lead from the bottom of the 
faucet. 
4. Guide the supply tube, threaded 
shank and wire lead through the hole in 
the deck.
5. Secure from beneath using the 
cupped washer and nut on the 
threaded shank.
6. If adjusting the Auto Time Out and/
or Water Shut O  Delay DIP switches, 
refer to the section below, “SWITCH 
SETTINGS.”
7. If installing the AC transformer, refer 
to the section below, “TRANSFORMER 
OPTION.” 