Installation Guide

8
SWITCH SETTINGS:
The EC-3130, EC-3132 & EC-3142 ChekPoint controller o ers settable water  ow
control adjustment selections. These selections are set by con guring a bank of DIP
switches located behind the sensor to the settings shown on the tables below.
To access the DIP switches:
1. Shut-o the water supply at the supply stops.
2. Using the L-Key provided, remove the handle and body screws. If the pre-set
temperature plug is installed it does not need to be removed.
3. Remove the temperature lever and adapter from the faucet body. Note: the adapter
has an o-ring seal and may require pliers to pull out from the body. Protect the
chrome  nish on the adapter from the jaws of the pliers.
4. Remove the faucet body from the base by pulling the body straight up.
5. Remove the battery to access the bank of DIP switches.
Figure 6:
Access to Dip Switch
Settings
6. Set the DIP switches to the desired
settings described on page 9.
7. Replace battery.
8. Carefully reinstall the body straight
down onto the base.
9. Reinstall the lever handle assembly
and body screw.
General Instructions
5. Remove the faucet body from the base by
pulling the body straight up.
6. Install the chrome body plug into the hole
from the inner side of the body as shown
below. The smooth face of the plug will be the
exposed size. Press the plug until bottomed.
7. Carefully reinstall the body straight down
onto the base.
8. Reinstall the body screw.
9. Turn on the supply stops.
Figure 5
body plug