Installation Guide
7
General Instructions
8. For a mixing faucet with 2 inlets, connect the check valve adapter end of the
exible supply hoses to the supply stops. Connect the other end of the supply
hose to the corresponding hot supply threaded shank and cold supply tube. Do not
overtighten.
9. For a single temperature faucet with one inlet shank, connect the check valve
adapter end of one exible supply hose to the single temperature water supply.
Connect the other end of the supply hose to the single inlet shank.
10. Turn on supply stops and check for leaks.
11. To test the sensor eye on/o function and switch settings (if set), place your hand
2 to 3 inches in front of the sensor. The LED will blink once and water will start to
ow.
12. Remove your hand from the area. If water does not stop owing within 2 seconds
or according the to the Water Shut O Delay set by SW(5) and SW(6), then the
sensor range will need adjusting (refer to “INSTRUCTIONS FOR SETTING THE SENSOR
RANGE”).
POINT-OF-USE TEMPERATURE ADJUSTMENT:
1. Push the lever on the right side towards the back for colder water.
2. Pull the lever towards the front for hotter water.
PRE-SET WATER TEMPERATURE ADJUSTMENT:
1. Using the L-Key provided, remove the handle and body screws.
2. Remove the temperature lever and adapter from the faucet body. Note: the adapter
has an o-ring seal and may require pliers to pull out from the body. Protect the
chrome nish on the adapter from the jaws of the pliers.
3. Using a at screwdriver, turn the brass spindle accessible through the hole where
the adapter was removed to adjust the water temperature to the desired setting:
clockwise for colder, counter clockwise for hotter.
4. After setting water temperature, shut-o the water supply at the supply stops.
Figure 4