Installation Guide

6
General Instructions
IMPORTANT:
· ALL ELECTRICAL WIRING IS TO BE
INSTALLED IN ACCORDANCE WITH
NATIONAL/LOCAL CODES AND REGULA-
TIONS.
· ALL PLUMBING IS TO BE INSTALLED IN
ACCORDANCE WITH
APPLICABLE CODES AND REGULATIONS.
· USE APPROPRIATE PRECAUTIONS
WHILE CONNECTING TRANSFORMER TO
120 VAC POWER SOURCE.
· DO NOT PLUG TRANSFORMER INTO
POWER SOURCE (RECEPTACLE) UNTIL
ALL WIRING IS COMPLETED.
· FLUSH ALL WATER LINES UNTIL WATER
IS CLEAR BEFORE CONNECTING FAUCET
TO SUPPLY STOPS.
Tools Required For Installation of
Faucets
· 8” (200mm) adjustable wrench
· VR Torx wrench (included)
· Basin wrench
· Slotted screwdriver, 3/16”
· Phillips head screwdriver, #1
· Pliers
Prior to Installation:
Prior to installing the T&S ChekPoint
Series Faucet, install the items listed
below:
· Scrub or wash-up sink
· Drain line
· Hot and cold water supply lines &
stops.
(Supply stops must be furnished by
installer or purchased from T&S.)
Tighten compression  ttings securely
on supply lines.
· (OPTIONAL) Provide electrical
receptacle within approximately 12’
from sink for plug-in transformer - 120
VAC, 2 amp service for each plug-in
transformer used.
Installation of EC-3130 & EC-3132
ChekPoint Faucets:
(Refer to Figures 1, 2, 3 and 4)
The EC-3130, EC-3132 & EC-3142
ChekPoint faucets have above deck
sensor electronics and temperature
control. Power is supplied by a 6V
lithium battery within the faucet
body. Another power option is an AC
transformer connected below the deck
to a lead terminal from the bottom of
the faucet.
1. Drill a Ø 1 ¼” hole where the faucet
is to be installed. Maximum deck
thickness is 1 ½”.
2. Pull the battery saver strip coming
from the bottom of the faucet. The LED
light in the sensor lens will light up and
icker.
3. If using the AC transformer, connect
the auxiliary power connector cable to
the wire lead from the bottom of the
faucet.
4. Guide the supply tube, threaded
shank and wire lead through the hole in
the deck.
5. Secure from beneath using the
cupped washer and nut on the
threaded shank.
6. If adjusting the Auto Time Out and/
or Water Shut O Delay DIP switches,
refer to the section below, “SWITCH
SETTINGS.
7. If installing the AC transformer, refer
to the section below, TRANSFORMER
OPTION.