Installation Guide

11
General Instructions
PROBLEM
No Water When Activated
Red LED in electronic eye
POSSIBLE CAUSE/SOLUTION
If red LED stays on or is  ashing:
1. Replace batteries.
1. Check supply stop(s); open if closed.
2. Debris in supply hose  lter washers
in 1/2” NPSM swivel end; remove, clean
and reinstall.
3. Debris in aerator or spray head;
remove, clean and reinstall
1. Check surroundings for factors that
can contribute to the false triggering;
for example, bright lights, highly
re ective surfaces, sunlight, etc.
2. Range too long; decrease sensor
range.
1. Debris in solenoid valve, won’t close
properly. Contact factory.
Very Low Flow or Slow Dribble
False Triggering
(Unit goes on by itself)
Continues to Run
(Even after power to faucet has been
reconnected)
TROUBLESHOOTING GUIDE