Installation Guide

10
General Instructions
To replace the battery:
1. Shut-o the water supply at the supply stops.
2. Using the L-Key provided, remove the handle and body screws. If the pre-set
temperature plug is installed it does not need to be removed.
3. Remove the Temperature Lever and adapter from the faucet body. Note: the
adapter has an o-ring seal and may require pliers to pull out from the body. Protect
the chrome  nish on the adapter from the jaws of the pliers.
4. Remove the faucet body from the base by pulling the body straight up.
5. Remove and replace the battery.
6. Carefully reinstall the body straight down onto the base.
7. Reinstall the lever handle assembly, if used, and body screw.
8. Open the supply stops.
INSTRUCTIONS FOR SETTING THE SENSOR RANGE:
The EC-3130 and EC-3132 faucets have an adjustable sensor with a default range set at
the factory. Should this range need to be changed, follow the steps below and refer to
Figure 6. The sensing distance is adjustable from 3/4” (2cm) to 6 11/16” (17cm).
1. Place the magnet provided on the upper right corner of the sensor for 5 seconds.
When the magnet is in place the solenoid will open.
2. After 5 seconds when the solenoid closes and the LED turns on, remove the magnet.
3. The LED will turn o indicating the sensor is now in set-up mode. Note: the sensor
will remain in set up mode for approximately 15 seconds. Then the LED will  ash 3
times before the sensor range returns to its previous setting.
4. While in set-up mode, hold your hand at the desired distance from the sensor for 3
seconds. The LED will blink.
magnet
sensor lens
5. After the 3 seconds, the blinking LED
will stay on for a few seconds then turn
o .
6. When the LED turns o , the new
range setting is saved
7. Even if the faucet loses power such as
when the battery is replaced, the setting
saved above will be kept.
Figure 7