Instructions / Assembly

A Maximum of (8) ChekPoint Faucets can
be Hardwire Connected and Powered by
EC-HARDWIRE ChekPoint Hardwire AC
Transformer. (Sold Separately)
*Available Water Flow Control Selections:
- Auto Time Out: 15 sec, 30 sec, 45 sec, 60 sec, 3 min, 20 min
- Shut Off Delay: 1 sec, 10 sec, 15 sec, 30 sec
- Auto Flush (30 Seconds After Every 12 Inactive Hours): ON or OFF
- Metering Mode: ON or OFF
ITEM
NO.
SALES NO. DESCRIPTION
1 B-0199-06-LF15A
VR 1.5 GPM Laminar Flow Device (Anti-Microbial)
w/ VR Key
2 015425-45 Vandal Resistant Key
3 019174-45 Sensor Cable Asssembly
4 016297-45 Inlet Hose, Faucet, 1/2" NPSM-F x 1/4" NPSM-F
5 019944-45 ChekPoint Control Module w/ Filter Tee
6 5EF-0002C AC Adapter - US Plug
7 5EF-0005 Supply Hose, 9/16-24 Female x 1/2" NPSM
8 002534-25 Close Nipple, 1/2" NPT
9 EC-FILTER Replacement Filter
JRM 11/10/20 Scale:
Model No.
Item No.
T&S BRASS AND BRONZE WORKS, INC.
18" Flexible Supply Hose
Date:
NSF 372 (Low Lead Content)
Travelers Rest, SC: 800-476-4103 • Simi Valley, CA: 800-423-0150 • Fax: 864-834-3518 • www.tsbrass.com
NSF 61 - Section 9
ANSI A117.1 (ADA)
2 Saddleback Cove / P.O. Box 1088
Checked:
Travelers Rest, SC 29690
NTS
UL 1951
2
of
2Sheet:JHB
DMH
Approved:Drawn:
EC-1210-08
Product Compliance:
ASME A112.18.1 / CSA B125.1
8" High Chrome Plated Brass Electronic Glass Filler: Single Hole Deck Mount,
High-Arc Rigid Nozzle w/ VR 1.5 GPM Anti-Microbial Laminar Flow Device,
AC/DC Control Module w/ Internal Flow Control Setting Switches, and
Product Specifications:
7
8
9
- Auto Flush = OFF
1
2
3
4
5
6
- Metering Mode = OFF
Flow Control Switches are Located
Behind Battery Compartment Cover
*Switches are Set to DEFAULT Position:
- Auto Time Out = 15 Seconds
- Shut Off Delay = 1 Second