Instructions / Assembly

4
Nozzle Installation:
Note: Nozzles should be installed
rst.
If installing Rigid Gooseneck
1. Apply te on tape or pipe joint
compound to threaded end of no.9.
2. Tighten no.9 rmly by hand into
no.2.
If installing Swivel Nozzle:
3. Insert no.9 or no.10 into no.2 and
rotate to front of sink.
4. Tighten no.16 rmly with a
wrench.
Faucet Installation:
6. Shut o water supply and drain
lines. Drill (2) two holes, approxi-
mately 1-1/4” [3 cm] diameter in
wall with 8” [20 cm]centers, where
you are installing no.1.
7. Apply te on tape or pipe joint
compound to water supply lines.
8. Connect no.2 to water supply
lines by attaching no.3 with eccen-
tric centers onto nipple supplied
by others and tighten no.3 against
wall. Make sure no.4 is in place. Nut
behind wall to be supplied by oth-
ers. Trim supply lines if necessary.
9. Turn on water supply and check
for leaks.
water supply line
wall
nut
9
9 or 10
11, 12,
14, 15
2
16
2
14
11
Enlarged View
15
2
4
3
For swivel repair or replacement of
(o-ring) no.15 and (sleeves) no.14:
5. Insert one no.14 onto no.11. Install
no.15 on no.11 and lubricate liberally
with provided no.17. Install second
no.14 onto no.11. (See Enlarged
View)
(supplied by others)
8”
[20cm]
General Instructions