OPERATION MANUAL PageMic8 Please follow the instructions in this manual to obtain the optimum results from this unit. We also recommend that you keep this manual handy for future reference.
TABLE OF CONTENTS 1. SAFETY PRECAUTIONS ...................................................................................... 3 2. DESCRIPTION ....................................................................................................... 5 3. FRONT AND REAR PANEL(FRONT PANEL ) ............................................. ....6 4. FRONT AND REAR PANEL(REAR PANEL) ......................................................8 5. CONNECTION AND SETTINGL ....................................................
1. SAFETY PRECAUTIONS Be sure to read the instructions in this section carefully before use. Make sure to observe the instructions in this manual as the conventions of safety symbols and messages regarded as very important precautions are included. We also recommend you keep this instruction manual handy for future reference.
SAFETY PRECAUTIONS When the Unit is in Use When Installing the Unit Do not place heavy objects on the unit as this may cause it to fall or break which may result in personal injury and/or property damage. In addition, the object itself may fall off and cause injury and/or damage. Never plug in nor remove the power supply plug with wet hands, as doing so may cause electric shock. When unplugging the power supply cord, be sure to grasp the power supply plug; never pull on the cord itself.
2.DESCRIPTION 1.The PageMic8 remote zone paging microphone work together with 8 ZONE PAGING MIC through universal industrial standard CAT5 cable for zone announcement or communication at a remote and different location from the control center. 2.Each matrix controller 8 ZONE PAGING MIC provides two RJ45 ports for the remote paging microphone. Maximum each system could support two remote zone paging microphone link together with the master 8 zone matrix controller.
3. FRONT AND REAR PANEL FRONT PANEL 1 2 3 4 5 6 7 8 910 1. GOOSENECK MICROPHONE 2. POWER INDICATOR The LED will be light on blue when power switch is placed at on position, which will be extinguished when power switch is placed at off position. 3. OUTPUT LEVEL METER 5 position LED output level meter to display the output status, green, green, green, amber to red. 4. TALK INDICATOR The LED will be light on blue when talk button is pushed, which will be extinguished when talk button is pushed back. 5.
NOMENCLATURE AND FUNCTIONS Label insert from here Length :20mm Width :6mm Distance from center to center 9mm 9. ZONE INDICATOR Dual color indicator LED is used to display the zone status. The indicator will be illuminated on blue under paging status and on amber under busy status. 10.
4. FRONT AND REAR PANEL REAR PANEL CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN AVIS: PUBLIC ADDRESS SYSTEM SERIAL NO : RISQUE DE CHOC ELECTRICUS -NE PAS QUVRIR MIC VOL. ON 0 10 CHIME VOL. 0 10 CHIME 2 TONE OFF 4 TONE OFF 11 POWER 24VDC COM 12 13 14 15 16 11.POWER SWITCH. The paging console is powered from the matrix through CAT5 cable.Power on when power switch is placed at on position, and power off when power switch is placed at off position. 12.DC 24V POWER INPUT.
5. CONNECTION AND SETTING 5.1 Onnection between the remote paging console and the extension keypad: The IDE communication cable is used to provide connection between the remote paging console and the extension keypad and between two extension keypads Connection through 10P IDE cable Extension keypad Remote paging Console 5.3 Extension keypad dipswitch setting: There are 4 address codes on both remote paging console and extension keypad, which are used to identify itself.
6.OPERATION GUIDANCE 6.1 Zone selection 6.1.1 Announcement shall be started after individual zone or all zone selection, the matrix will feedback to the remote paging console's or extension keypad's inquiry, the permission of paging or busy will be displayed as different indicator: blue and amber. 6.1.