2. Technical Data
Model
HWW 3000 INOX
HWW 4500 INOX
Mains voltage / frequency
230 V ~ 50 Hz
230 V ~ 50 Hz
Nominal performance
550 Watt
1,200 Watt
Protection type
IP 44
IP 44
Suction port
30.93 mm (1 “), female
30.93 mm (1 “), female
Pressure port
30.93 mm
(1 “)
, female
30.93 mm
(1 “)
, female
Max. flow rate (Q
max
)
1)
2,950 l/h 4,350 l/h
Max. pressure
3)
4.2 bar 5.0 bar
Max. delivery height (H
max
)
1), 3)
42 m
50 m
Max. suction height
9 m
9 m
Volume of the pressure tank
18 l
22 l
Max. size of the solids being pumped
3 mm
3 mm
Max. permissible operating pressure
6 bar
6 bar
Min. ambient temperature
5 °C
5 °C
Max. ambient temperature
40 °C
40 °C
Min. fluid temperature
2 °C
2 °C
Max. fluid temperature (T
max
)
35 °C
35 °C
Max. cut-in frequency in one hour
40, evenly distributed
40, evenly distributed
Length of connection cable
1.5 m
1.5 m
Cable type
H05RN-F
H07RN-F
Weight (net)
9.9 kg
14.4 kg
Guaranteed sound power level (L
WA
)
2)
78 dB
86 dB
Measured sound power level (L
WA
)
2)
75.2 dB
84.5 dB
Sound pressure level (L
pA
)
2)
67.2 dB 78.9 dB
Dimensions (L x D x H)
46 x 27 x 47 cm
48 x 28 x 56 cm
Item no.
31143
31140
1)
2)
3)
The values were determined with free, unreduced in- an outlet.
Noise emission values obtained according to the EN 12639 regulation. Measurement method according to EN ISO 3744.
Due to the factory pre-set switch off pressure of the pressure switch, pressure is limited to approx. 3 bar (30 m delivery
head). The theoretically achievable pressure of the pump unit of the domestic water supply can reach the value specified
under “Max pressure”. Consult a qualified specialist, to adapt the pressure circuit to your requirements if necessary, see
also the chapter “Setting the pressure switch”.
3. Range of use
Booster sets from T.I.P. are self-priming electrical pumps with a mechanical or electronic pump control system for
automated operation. These high-quality products with their convincing performance data were developed for the
various purposes involved with irrigation, domestic water supply and pressure boosting, as well as for discharging
water at a constant pressure. The devices are suitable for pumping clean, clear water.
The typical areas of use of booster sets include: Automatic domestic water supply with grey water from wells and
cisterns, automated irrigation of gardens and garden beds and sprinkling, pressure boosting within the domestic
water supply system.