• Check the quartz glass for damage.
• Reassemble the whole thing in the reverse order and be sure to install the various components correctly
• Switch on the UVC clarifier to check that it works as described above
TFP 10000 UV 11, TFP 15000 UV 13:
• Disconnect the UVC clarifier and pump from the power supply and secure them against being switched
on again
• Please observe the above safety measures
• Remove the four screws from the top UVC cover on the filter cover.
• After removing the screws, remove the UVC cover including the lamp socket and ensure that the O-ring
on the lamp socket is not lost. Do not pull on the power cord in the process
• Now it is possible to loosen the fixing nut at the beginning of the quartz glass piston and carefully remove
the quartz glass piston. Take care not to damage the O-ring
• Carefully clean the quartz glass piston (5) from the outside and remove any limescale deposits with a
suitable solvent. Rinse off thoroughly before installation.
• Check the quartz glass for damage.
• Reassemble the whole thing in the reverse order and be sure to install the various components correctly
• Switch on the lamp to check that it works as described above.
6.4. Replacing the UVC tube:
We recommend only having the UVC tube replaced by our qualified personnel.
Damage to the quartz glass piston or the clarifier unit due to improper assembly/disassembly is
not covered by the warranty.
Caution! Do not touch UVC tube (3) directly with your hand; put on cotton gloves!
Do not dispose of old, broken UVC tubes in the household waste. Consult your local disposal company. Do
not use any sharp-edged tools. If the quartz glass piston or O-rings are faulty, they must always be replaced.
TFP 5000 UV 9:
• Disconnect the UVC clarifier and pump from the power supply and secure them against being switched
on again.
• Please observe the above safety measures
• Remove the three screws from the top UVC cover on the filter cover.
• Disassemble the UVC cover after removing the screws.
• Loosen the UVC socket with ballast unit by turning it slightly anti-clockwise (approx. 30°).
• Remove the lamp socket, taking care not to lose the O-ring on the quartz piston seat. Do not pull on the
power cord in the process.
• Then remove the old UVC tube (3) by gently pulling on the base and replace it with a new original
replacement tube (see item 9 “Service”). Make sure that all parts of the UVC unit are dry
• Check the quartz glass for damage.
• Reassemble the whole thing in the reverse order and be sure to install the various components correctly
• Switch on the lamp to check that it works as described above.
TFP 10000 UV 11, TFP 15000 UV 13:
• Disconnect the UVC clarifier and pump from the power supply and secure them against being switched
on again
• Please observe the above safety measures
• Remove the four screws from the top UVC cover on the filter cover.
• After removing the screws, remove the UVC cover including the lamp socket and ensure that the O-ring
on the lamp socket is not lost. Do not pull too hard on the power cord in the process.
• Now it is possible to loosen the fixing nut at the beginning of the quartz glass piston and carefully take off
the quartz glass piston.
• Then remove the old UVC tube (3) by gently pulling on the base and replace it with a new original
replacement tube (see item 9 “Service”). Make sure that all parts of the UVC unit are dry
• Check the quartz glass for damage.
• Reassemble the whole thing in the reverse order and be sure to install the various components correctly
• Switch on the lamp to check that it works as described above.