User manual
The pump is not suited to discharge saltwater, faeces, inflammable, etching, explosive or
other hazardous liquids. Please observe the max. temperature of the liquids to be discharged
stated in the technical data.
Inside the pump, lubricants are used which may contaminate the liquids being discharged in
case of any improper operation or damage of the device. The lubricants used are biologically
degradable and non-hazardous to health.
3. Technical Data
Model DRAIN 6000/36
Mains voltage / frequency 230 V ~ 50 Hz
Nominal performance 950 Watt
Protection type IP X8
Pressure port 41.91 mm (1 ¼ “), male
Max. flow rate (Q
max
)
1)
6,000 l/h
Max. pressure 3.4 bar
Max. delivery height (H
max
)
1)
34 m
Max. submersion depth
7 m
Max. size of the solids being pumped 2 mm
Max. fluid temperature (T
max
) 35 °C
Max. cut-in frequency in one hour 30, evenly distributed
Length of connection cable 10 m
Cable type H07RN-F
Weight (net) ~ 8.5 kg
Min. self-priming level (A)
2)
120 mm
Min. suction level (B)
2)
27 mm
Cut-in level (C)
2)
420 mm
Cut-out level (D)
2)
230 mm
Dimensions (L x D x H) 17 x 16 x 38.5 cm
Item no. 30136
1)
2)
The values were determined with free, unreduced outlet.
The values between brackets refer to the illustrations given at the end of these operating instructions.
4. Scope of delivery
The scope of the delivery of this product includes:
One pump with connection cable, one connection port, one operating manual.
Please verify that the scope of delivery is complete. Depending on the purpose of the application, additional
accessories may be necessary (please refer to the chapters titled "Installation", “Automation with special
accessories” and “How to order spare parts“).
If possible, keep the packing until the warranty period has expired. Please dispose of the packing materials in an
environmental-friendly manner.
5. Installation
5.1. General installation information
During the entire process of installation, the device must not be connected to the electrical
mains.
The pump and the entire connection system have to be protected from frost.
All connection lines have to be perfectly tight since leaking lines may affect the performance of the pump and
cause considerable damage. If required, please use a suitable sealant to make the installation airtight.
2