4.12 SMS notice of Arm/Disarm
After user set the SMS notice of Arm/Disarm function on, the panel will send SMS notice to users
when panel armed and disarmed, so users can know the panel’s situation. The default value is off.
(1) Enter into Menu, press【
】or【 】, select “System Settings”,press【 】to confirm.
(2) Press【 】or【 】, select “Arm SMS”or“Disarm SMS”,press【 】to confirm
℃press“1 = YES” to turn ON,press“0=NO” to turn OFF。
4.13 Reset to defaults
This function is to reset all values to default values, the phone number will be deleted, but the coded
accessories won’t be deleted.
(1) Enter into Menu, press【
】or【 】, select “System Settings”,press【 】to confirm.
(2) Press【 】or【 】, select“Reset”,press【 】to confirm, Reset to defaults
4.14 Check the alarm logs
Users can check alarm logs in anytime, the system can store 40 alarm logs at most.
(1) Enter into Menu, press【
】or【 】, select“Events”,press【 】to confirm
(2) Press【
】or【 】, select“View”, press【 】to confirm
(3) LCD display shows the log’s time, alarm mode, arm/disarm record etc..
Delete logs: in step (2) select “Delete”,press【 】to confirm