Content Chapter 1 Knowing the alarm host 1.1 Features 1.2 Technical Parameters 1.3 Packing List 1.4 Knowing the alarm host Chapter 2 Alarm phone&SMS number settings 2.1 Alarm phone setting. 2.2 SMS numbers setting Chapter 3 Accessories settings 3.1 Remote controller&keypad settings 3.2 RFID tag settings 3.3 Wireless sensor settings Chapter 4 System setting& alarm logs 4.1 Date and time 4.2 Exit/Entry Delay 4.3 Timing Arm and Disarm 4.4 Remote Control Switch 4.5 SIM Card Notice Switch 4.6 AC / DC Notice 4.
Chapter 5 Daily use 5.1 Preparations before use 5.2 Arm/disarm/SOS daily use 5.3 RFID tag use 5.4 Phone calling 5.5 Voice record 5.6 Menu settings Chapter 6 Remote control via APP&SMS&call 6.1 APP operation 6.2 SMS operation 6.3 Remote control via calls Chapter 7 Maintenance and Troubleshooting 7.1 Maintenance 7.
Chapter 1 Knowing the GSM alarm host 1.
1.3 Packing List: Alarm host&bracket x1 PIR detector&bracket x1 Wireless door sensor&adhesive tape x1 RFID card x2 Bulged tube & screw x 2 User manual x1 1.4 Knowing the alarm host 1.4.
1.4.2 Panel back view Anti-tamper switch Built-in speaker Microphone Power adapter jack Battery switch SIM card slot Wired siren jack Wired connection 1.4.
Chapter 2 Alarm phone&SMS number settings In disarm status, enter administrator password(Default value is 1111), press 【 into settings. Press 【 】key to enter 】key for exit if need. 2.1 Alarm phone setting. User can set 6 alarm phone numbers and 4 SMS mobile numbers. When alarming, the system will send SMS alarm message to SMS numbers by turn, then call alarm phone numbers by turn. 2.1.1 Add alarm phone numbers.
(1) Enter into menu settings, select “Phone numbers”, press 【 】or【 (2) Press 【 (3) Press【 【 】or【 】 ,select “Add”,press【 】to confirm. 】to confirm. 】 ,select “SMS Number(1~4)”by turn(it is after phone number 6), press 】to confirm. (4) Enter SMS number which you want to set,Press【 】to confirm. Notice: If user want to check or change saved phone numbers, enter into “SMS Number(1~4)”then check or change. The max data of phone number is 16 data. 2.2.2 Delete SMS numbers.
(2)Press【 】or【 】 ,select “Remote & Keypad”, and press【 】to confirm. (3)Press【 】or【 】, select “RC 01-10” by turn, and press 【 】to confirm. (4)Press【 】or【 】, select “Add”, and press【 】to enter into coding. LCD display shows “Synchronize”, (5)Press any key of remote or keypad to let it transmit a wireless signal to alarm host. Then the alarm host beep once, indicates coding is successful. If beep twice and display “Already added” on LCD,it indicates repeated coding.
(2) Press【 】or【 】 ,select “RFID Tag”, and press【 (3) Press【 】or【 】, select “RFID (1~50)” by turn, and press 【 (4) Press【 】or【 】, select “Add” by turn, and press【 】to confirm. 】 to confirm. 】to enter into coding. LCD display shows “Synchronize”. (5) Closea RFID tagto the induction area of alarm host panel. Then the alarm host beep once, indicates coding is successful. If beep twice and display “Already added” on LCD,it indicates repeated coding. 3.2.
(1) Enter into menu setting, press【 】or【 】, select “Accessories”, and press 【 】to confirm. 】or【 (2) Press【 (3) Press【 】or【 (4) Press【 】or【 】 ,select “Wireless Sensors”, and press【 】, by turn select “Sensor (01~99)”, and press 【 】, select “Add”, and press【 】to confirm. 】 to enter into coding. 】to enter into coding. LCD display shows “Synchronize” (5) Trigger the sensor and let it transmit wireless signal to alarm host, then the alarm host beep once, indicates coding is successful.
normally and can trigger host to alarm. User need to set entry/exit delay time in advance. Please refer to 4.2. Home Sensor: Sensors of home defense zones. The home sensors protect the living areas of the house like living room, bedroom, the alarm host will ignore the home sensors if user stay arm the host but activate other sensors. 3.3.3 Name wireless sensors (1) Enter into menu setting, press【 】or【 】, select “Accessories”, and press 【 】to confirm.
Chapter 4 System setting 4.1 Setting date and time 4.1.1 Date setting (1) Enter into menu setting, press【 】or【 】, select “System Settings”, and press 【 】 to confirm. (2) Press【 】or【 】 ,select “Date and Time”, and press【 (3) Press【 】or【 】 ,select “Date”, and press【 (4) Input the date and press【 】to confirm. 】to confirm. 】to confirm. 4.1.2 Display Format of date and time (1) Enter into Menu Setting,press【 】or【 】,select System Settings, press【 】key to confirm.
(4)Input your local(current) time,press【 】key to confirm. Please reset the time with the recovery of power supply. 4.2 Entry/Exit Delay By setting this functions, the alarm host will ignore the delay sensor in the exit/entry delay time, wait for user exiting or entering the house; after the delay time, the delay sensor will work normally and can trigger host to alarm. About the delay sensor, please refer to 3.3.2. 4.2.
beep more quickly. 4.3 Timing Arm and Disarm User can set up timing arm/disarmas your scheduleto avoid the repetitive operation. 4.3.1 Timing arm (1) Enter menu setting , press【 】or【 】,select “System Settings”, press【 (2) Press【 】or【 】,select “Sched Arm/Disarm”,press【 (3) Press【 】or【 】 ,select “Auto Arm Time”,press【 (4) Input the time for timing Arm, press【 】key to confirm 】key to confirm 】key to confirm 】 key to confirm 4.3.
(1) Enter Menu Setting, press【 (2) Press【 】or【 】or【 】,select “System Settings”, press【 】,select “SIM card notice”, press【 】key to confirm 】key to confirm (3) Press“1 = YES” select Switch ON,Press“0=NO” select OFF. 4.6 AC/DC Notice. AC/DC Notice means when the AC is Failure/Recovery or Battery is low battery, the LCD will display and remind user.
(2) Press【 】or【 】 ,select “Access password”, press【 】key to confirm. (3) Press【 】or【 】 ,select “Admin password”, press【 】key to confirm (4) Input 4 digits Password, Press【 】to confirm. Warm Prompt:If you forget your Administrator password, and can’t set the panel, please contact with your dealer. 4.8.2 User Password With user password, user can disarm alarm host by keypad, or remotely control host by phones. Its default value is 2222.
4.9 Ring times Ring times means the times of host ringing before it take the phone call by preset phone numbers. Its default value is 6 times. (1) Enter Menu Setting, press【 (2) Press【 】or【 】or【 】 ,select “System Settings”, press【 】 ,select “Ringing Times”, press【 (3) Input (0-9) times, press【 】key to confirm. 】key to confirm. 】key to confirm. 4.10 Cycle Call times Cycle call times means the times of alarm host calling the preset phone numbers by circle when alarm. Its default value is 6 times.
4.11.2 ON/OFF wired siren User can set the wired siren be on or off, default value is on. (1) Enter into Menu, press【 】or【 】 ,select “System Settings”,press【 (2) Press【 】or【 】 ,select “Siren Setup”,press【 】to confirm. (3) Press【 】or【 】 ,select “Wired Siren”,press【 】to confirm. 】to confirm. (4) Press“1 = YES” to turn ON,press“0=NO” to turn OFF. 4.11.3 ON/OFF wireless siren User can set the wireless siren be on or off, default value is on.
4.12 SMS notice of Arm/Disarm After user set the SMS notice of Arm/Disarm function on, the panel will send SMS notice to users when panel armed and disarmed, so users can know the panel’s situation. The default value is off. (1) Enter into Menu, press【 (2) Press【 】or【 】or【 】 ,select “System Settings”,press【 】 ,select “Arm SMS”or“Disarm SMS”,press【 】to confirm. 】to confirm ℃press“1 = YES” to turn ON,press“0=NO” to turn OFF。 4.
(1) First insert the output plug of adapter into power jack of panel (2) Then insert the adapter into AC power socket Notes:AC power is for normal use, the built-in rechargeable battery is backup power, use only when AC power fails. 5.1.2 SIM card inserting Insert the SIM card into slot by correct direction. Notes:After insert the SIM card, itwill search GSM signal soon. 5.
Press Stay arm【 】key,host releases prompt “System armed”, Stay arm indicator LED on, all the defense zones enter into Armstatus except for home zones. In home zones user can act freely and won’t trigger alarm, but other zones are in alert status, can protect users from invasion or other danger. (3)Disarm Input user password, press Disarm【 】key, panel releases prompt “System disarmed”, Disarm indicator LED on, the system will enter into Disarm status.
Close the RFID card to the RFID tag induction area, Green LED will flashes once, you can disarm the system. 5.4 Phone calling User can use the alarm host make normal call to any phone number in standby status, first press calling【 】key,LCD gives hints “Please Input Phone Number”, then input the phone number you’d dial, press 【 Press【 】key to wait for the connection. Press clear【 】key to end the call. 5.5 Voice record 】key to clear wrong input.
The system has the voice record function. Keep pressing 【 】 key for 3s to record 10Svoice message. After recording, the panel will automatically playthe voice; Keep pressing 【 】 key for repeat play. The new record will cover the last one 5.6 Menu settings(Refer to chapter 2,3,4) In disarm status, Input the administrator password(default value is 1111), press【 】 ,enter intomenu setting. Chapter 6 Remote control via APP&SMS&call 6.1 APP operation We have APP for both Android and IOS system.
(3)Delete host account IOS mobile: press [Edit], then press【Delete】, the added host account will be deleted. Android mobile: press[Edit], long press the phone number, then will come out the dialog window of deleting account, press[Finish], the added account will be deleted. 6.2 SMS operation If no SMS numbers are saved, user can control the panel to arm, disarm, open or close the siren ect. by SMS of any mobile number.
The panel will send one SMS “SMS DISARM” back to your mobile, remind you disarm successfully. 6.2.4 Monitor Command “3” Edit SMS “3” and send to the panel number with your mobile phone The panel get the SMS, then dial back, pick up the phone you can monitor the house with mobile. 6.2.5 Bilateral intercom Command “4” Edit “4” and send to the panel number with your mobile phone The panel get the SMS, then dial back, pick up the phone you can intercom 6.2.
When alarm, the alarm host dial the pre-set phone numbers, users pick up the phone, and remotely control by commands (please refer to the command list) 6.3.2 Dial the alarm host number to remotely control (1)Dial the host number with any telephone, after connect, the panel will beep once. (2)Enter administrator Password,press【 】to confirm. After the panel beeps once, then you can remotely control by command. (3)If user enter into wrong password by 3 times the panel will hang up.
(3) Don’t store or use alarm host in dusty or dirty places, otherwise it may damage the electronic components. (4) Please do not place the alarm host in a hot place. High temperatures can shorten the life of electronic devices, damage batteries, and melt or deform the plastic. (5) Do not store the alarm host in a very cold place, otherwise when the alarm host is warming up, it will cause moisture inside of the panel, which may damage circuit boards.
7.
Appendix Table 1: Contents & meaning on LCD System status Standby Arm/disarm Display Meaning AC Power Failure No AC power Panel low bat Low battery of backup battery Sen.
Menu setting on LCD Main menu Sub menu 1 Sub menu 2 Sub menu 3 Alarm Number1-6 Add Phone Numbers (Phone number 1-6) - SMS Number1-4 (SMS number 1-4) Phone Numbers (Phone number) - Alarm Number1-6 Del Phone Numbers (Phone number 1-6) (Delete phone number) SMS Number1-4 (SMS number 1-4) Remote& Keypad RC 01-10 (Control/Empty) (Remote controller and (Remote controller 01-10) wireless keypad) (coded/not coded) Delete All? Sure? - - All(Delete all) RFID tag 01-50 Delete(Delete single)
0=OFF - SIM card notice 1=ON - (Notice of SIM card existing 0=OFF - or not) 1=ON - 0=OFF - 1=ON - 0=OFF - Admin password Admin password User password User password Coercion PWD Coercion PWD (Coercion password) (Coercion password) 0-9(0-9 times) - AC/DC notice Keypad sound Access password Ringing times Call times 0-9(0-9 times) (Dialing times) Siren alert time 0-9: Minute Wired siren 1=ON 0=OFF Siren setup Wireless siren System Settings 0=OFF Built-in siren Events Arm SMS
This device complies with part 15 of the FCC Rules. Operation is subject to the condition that this device does not cause harmful interference Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.