User's Manual

AppendixB: Command
Items Commands Descriptions Remarks
1. Connection
Setting
A(addr) Setting for the address of
device to be connected
addr: 12 numbers in Hex
2. Baud Rate
Setting
B(BR) Setting for baud rate.
BR(Baudrate): 0 ~ 7
0: 1200, 1: 2400
2: 4800, 3: 9600
4: 19200, 5: 38400
6: 57600, 7: 115200
3. PIN
Number
Setting
E(PIN
/Enter)
Setting for authentication /
ciphering.
PIN: 16 letters (max)
Enter: deactivated
After authentication and
ciphering, two adapters
are to be connected if
their PIN numbers are
the same.
4. Flow
Control
Setting
F(FC)
Setting for flow control
FC: 0 ~ 1
0: None
1: Hardware
5. Search
Timeout
Setting
G(TO)
Setting for search timeout
TO(timeout): 0 ~ 999
Effective in connection
mode 2.
Default: 10 seconds
6. Maximum
Search
Setting
H(NO)
Setting for the maximum
number of devices to be
searched
NO(Respondents): 0 ~ 999
Effective in connection
mode 2.
Default: 10
7. Search
Execution
I(TO,NO) Search for Bluetooth devices
connected
TO(timeout): 0 ~ 999
NO(correspondents): 0 ~ 999
Effective in connection
mode 2.
Search will be
completed when it
reaches either timeout
or the maximum number
of correspondents.
8. Search
Response
Setting
J(E/D)
Setting whether to respond to
search request
E: Enabled
D: Disenabled
Effective in connection
mode 1.
9. Power
save setting
K(E/D) Setting for power save mode
E: Enabled
D: Disenabled
10.
Connection
Mode Setting
M(mode)
Setting for connection mode
The default setting for WCS-
232 is connection mode 0,
and connection modes 1,2
are used for the connection
with other Bluetooth devices.
Mode: 0 ~ 2
0: 1:1 connection
1: connection waiting
2: wait for user
command
11. Name
Setting
N(name)
Setting for friendly name.
Name: 30 letters (max.)
Along with the address,
it is available for ID.
12. Parity Bit
Setting
P(PA) Setting for parity bit.
PA: 0 ~ 2
0: None
1: Odd
2: Even
13.
Connection
Timeout
Setting
Q(TO)
Setting for timeout
connection.
TO(timeout): 0 ~ 999
Effective in connection
mode 2
14. Stop Bit
Setting
S(ST) Setting for stop bit.
ST: 0 ~ 1
0: 1 Stop
1: 2 Stop
15.
Connection
Execution
T(addr[,TO])
Connection to a specific
device.
addr: 12 numbers in Hex
[TO](timeout): 0 ~ 999
Effective in connection
mode 2
16. Execution
Cancellation
U Cancellation of device search
and connection command.
Effective in connection
mode 2
17. Setting
Confirmation
V Displays current setting. Software version
information included
18. CoD W(CoD) Setting for class of device. Default: “001F00”