User's Guide
52
Parity=N/E/O (Default=N)
Stopbit=1/2 (Default=1)
Description
The Serial parameters can be set or changed only if SW config mode is selected in dip
switch. The factory default is 9600, N, 1.
To take effect the ATZ command must be used or Powercycle the unit.
Example
AT+UARTCONFIG,115200,N,1
B.3.5. AT+USEDIP?
Response
m
Purpose
Check the Baud rate set by the dip switch
Description
m=0: Dip switches are set to ‘S/W Config’
m=1: Please view the dipswitches to view your baud rate.
B.3.6. AT+BTINFO?
Response
112233445566,DeviceName,Mode,Status,Auth,Encryp,FlowControl
OK
Purpose
Display Bluetooth settings
Description
The current Bluetooth settings are displayed including BD address, Device name,
Operation mode, Operation status, Authentication, Data Encryption, and Hardware Flow
Control. The initial value of Device name is ‘WCSv2.0.0-445566’. WCS stands for WCS-
232, v2.0.0 for the version of firmware, and 445566 for the last 6 digits of BD address.
Mode=MODE0/MODE1/MODE2/MODE3
Status=STANDBY/PENDING/CONNECT
Auth=0/1 (Authentication is not activated when 0)
Encrypt=0/1 (Encryption is not activated when 0)
FlowControl=HWFC/NoFC
Example
000B530011FF,SYSTEMBASE,MODE0,PENDING,1,1,HWFC
B.3.7. AT+BTINQ?
Response
112233445566,FriendlyName,CoD
112233445566,FriendlyName,CoD
112233445566,FriendlyName,CoD