User's Guide
20
Table 3-5 Hardware Flow Control Settings by Dipswitches
Hardware Flow Control
Handshaking
No Use
Use
* Note: You cannot set the WCS-232 to a Baud rate of 1200 and 230K by way of the Dipswitch. If you
want to use them, to set these speeds, please configure the dipswitch to S/W Config setting and use
WCSConfig or AT commands. Please refer to WCSConfig and Appendix B.3.4 AT+UARTCONFIG,
Baud rate,Paraty,Stopbit.
3.8. Pairing Button
WCS-232 provides Pairing Button for instant configuration without a PC to make an automatic
connection between two WCS-232s. In this example we will refer to the two WCS-232s as SD1 and
SD2. (Only single connection mode)
Step 1. Turn on SD1 and SD2 and reset both of them by pressing Factory Reset Button.
Step 2. Press the Pairing Button of SD1 for 2 seconds until Mode LED blinks 3 times every 3 seconds.
Keep the power ON.
Step 3. Press the Pairing Button of SD2 for 2 seconds until Mode LED blinks 3 times every 3 seconds.
Now press again the Pairing Button for 2 seconds until Mode LED blinks every second.
Step 4. Wait for SD1 & SD2 to connect to each other until the Connect LED’s of SD1 and SD2 blink
every 1 second. It takes about 10 seconds to make a connection. If there are many Bluetooth devices
nearby, it may take longer.
Step 5. Turn SD1 off and on. Mode LED blinks twice in green every 3 seconds.
Step 6. Turn SD2 off and on. Mode LED blinks in green every second.
Step 7. Now SD1 and SD2 are configured to make automatic connection to each other, whenever they
are powered on.
Using a pair of WCS-232 in this fashion is similar to that of using a wireless serial cable.
* Note: When using the pairing buttons, the Command Response option will be deactivated automatically.
The WCS-232 will not send the response messages such as OK, Connect and Disconnect.
Table 3-6 Pairing Process by Pairing Button
SD1
Status
LED
SD2
Status
LED
1. Factory reset
Mode0
Mode LED turns on
1. Factory reset
Mode0
Mode LED turns on