User's Guide
19
data becomes large, the possibility of data loss becomes greater.
For large data transmissions, the use of hardware flow control is highly recommended.
3.6. Reset to Factory Defaults
To set all the configuration settings to its factory default parameters, press the reset button, depicted in
Fig. 3-1. Press and hold (for at least 1 sec) the reset button with a narrow pointed tool like paper clip.
Reset works only when power is on.
3.7. Dipswitch
With the combination of 4 slot dipswitches, baud rate and hardware flow control can be set.
Figure 3-1 The WCS-232 Dipswitch
Upper 3 dipswitches are used for setting the baud rate, and bottom dipswitch is used for setting hardware
flow control option. If the baud rate needs to a baud rate not shown below, WCSConfig or terminal
program should be used to set these speeds. To set a baud rate not shown below the dipswitches
should be in the S/W Config setting. When in the S/W Config setting the baud rate will go back to 9600
as default.
Table 3-4 Baud rate Settings by Dipswitches
Baud rate
2400
4800
9600
19.2K
38.4K
57.6K
115.2K
S/W
Config
Pairing Button
Dip switch