WCS-232_v6.0_User Manual_Eng_DM v1.0.1
WCS-232 v6.0
User Manual
63
C.25. S52: Low Power Timeout (default: 5)
The low power timeout value and the unit is seconds. The default is 5 seconds.
If there is no data communication for the set time, it enters low power mode and wakes up from low power mode
when the data comes in again.
C.26. S54: BD Address of Last Connected Device
Stores the address of the Bluetooth device that was last connected to TASK2 in multi connection mode.
C.27. S55: BD Address of Last Connected Device
Stores the address of the Bluetooth device that was last connected to TASK3 in multi connection mode.
C.28. S56: BD Address of Last Connected Device
Stores the address of the Bluetooth device that was last connected to TASK4 in multi connection mode.
C.29. S57: Slave Disconnect Timeout (default: 3)
Sets the amount of time the master waits without sending data when the slave cannot receive data in multi-mode.
No data will be sent to other normal slaves during this time. If the slave cannot receive data after the specified, time,
it disconnects the slave. However, when slave starts receiving data before the set time pass, it stops waiting without
sending the data and starts to communicate normally. The setting value must be bigger than 0 and smaller than
Supervision Timeout(S37). (Unit: seconds)
C.30. S58: MAX TX POWER (default: 0)
Sets the maximum wireless output value. After setup, it will reboot and apply the changes automatically.
(There may be some errors depending on devices)
Setting Value
dBm
0
Use default chip setting value
1
-12