S6=0, disable low power mode
S6=1, enable low power mode
When enabling low power mode, it will enter a low power state if there is no data communication for a certain period
of time and wake up when there is data communication again.
C.5. S10: Enable Response Message (default: 1)
S10=0, WCS-232 does not send response message to the host
S10=1, WCS-232 sends response message to the host
Sets whether WCS-232 sends messages to the host such as OK, ERROR, CONNECT and DISCONNECT. If set to
1, send response messages to the host. If you do not want these messages to be sent to the host during Bluetooth
connection, set to 0 to disable this function.
C.6. S11: Enable Escape (default: 1)
S11=0, does not allow escape sequence character (operating status cannot be changed)
S11=1, allows escape sequence character (operating status can be changed from online to command standby)
Controls the Escape sequence character function. If set to 1, the escape sequence character can be used in online
status, and it can be changed to the command standby status. If set to 0 to disable this function, it cannot be changed
to command standby status from online status. Also, it is effective in transmission and reception side by omitting the
detection process of the Escape sequence character for data received from UART.
C.7. S12: Clear Data Buffer When Disconnected (default: 1)
S12=0, WCS-232 does not clear the data buffer received from host system when disconnected.
S12=1, WCS-232 clears the data buffer when disconnected.
If set to 1, it clears the data stored in the internal buffer of WCS-232 received from the host when disconnected.
C.8. S13: Enable DCD Signal (default: 1)
S13=0, DCD signal off
S13=1, DCD signal on