WCS-232_v6.0_User Manual_Eng_DM v1.0.1

WCS-232 v6.0
User Manual
43
Description
Factory default values are 9600, N, 1. The dip switch must be set to SWConfig mode for
application. You must reset software or turn the power off and on to take effect after the
change. The flow control option can only be changed with the dip switch.
Example
AT+UARTCONFIG,115200,N,1
B.3.5. AT+USEDIP?
Response
m
Function
Set the Baud rate and verify whether it is in use with the dip switch
Description
m=0: If the transmission speed combination of the dip-switch is 'SWConfig'.
m=1: If the transmission speed combination of the dip-switch is set to a specific
transmission speed
B.3.6. AT+BTINFO?
Response
112233445566,DeviceName,Mode,Status,Auth,Encryp,FlowControl
OK
Function
Display Bluetooth related setting values
Description
Used to refer to Bluetooth settings. It displays BD address, device name, operation mode,
operating status, whether authentication, encryption or hardware flow control is enabled.
Initial value of FriendlyName is as ‘WCSv2.0.0-445566’. WCS stands for WCS-232, v2.0.0
for firmware version, and 445566 for the back six digits of the BD address.
Mode=MODE0/MODE1/MODE2/MODE3
Status=STANDBY/PENDING/CONNECT
Auth=0/1 (disable/enable)
Encrypt=0/1 (disable/enable)
FlowControl=HWFC/NoFC (enable/disable)
B.3.7. AT+BTINQ?
Response
112233445566,FriendlyName,CoD
112233445566,FriendlyName,CoD
112233445566,FriendlyName,CoD
OK
Function
Search for peripheral Bluetooth devices waiting to be scanned