WCS-232_v6.0_User Manual_Eng_DM v1.0.1

WCS-232 v6.0
User Manual
31
4.2 Configuration
All slaves must be in connection standby state (Mode 3 or 2) and master attempts to connect to each slave.
First, wsitch to the desired multiple access mode with AT+MULTI,x command, which will be automatically reboot after
performing.
AT+MULTI,0
Single Connection mode
AT+MULTI,1
Multi-Drop mode
AT+MULTI,2
Node Switching mode
Table 4-1 AT+MULTI,x
Manual Connection
Automatic Connection
ATD000195000001
CONNECT000195000001
+++
OK
ATD000195000002
CONNECT000195000002
+++
OK
ATD000195000003
CONNECT000195000003
+++
OK
ATD000195000004
CONNECT000195000004
+++
ATS46=000195000001
OK
ATS54=000195000002
OK
ATS55=000195000003
OK
ATS56=000195000004
OK
AT+MULTI,1 or AT+MULTI,2
OK
AT+BTMODE,1
After reboot, master attempts
connection automatically
Table 4-2 Multi connection mode settings
Enter slave address to four S-Registers(S46, S54, S55, S56), set master to Mode 1 to keep the connection stable.
After rebooting, if the registry contains an accessible slave address, the message AUTO CONNECT will be displayed
behind the corresponding TASK.
TASK1 OK AUTO CONNECT
TASK2 OK
TASK3 OK AUTO CONNECT
TASK4 OK