uLory User Guide
17
follows: Length=7, STXL=3, ETXL=3, STX=31,32,33, ETX=34,35,36, Time=100. If 5671237456
is entered with less than the 1-second-interval, the number 567 will be ignored being
considered as not STX because it does not satisfy the condition of Length but the second
priority condition. In other words, only the number 7 will be recognized as a result of
recognition of 123 for STX and 456 for ETX.
Setup via utility (LoryView)
The utility provided along with uLory is available on http://www.sysbas.com where users can
download the data from the library of the homepage for the customer convenience. Users
can use LoryView for communication, reset, initialization and firmware update, and find the
detailed instructions on the use in the LoryView manual.
<LoryNet Mode>
LoryNet is an IoT platform with virtual cable that enables smooth communication as if it
were reading and writing to file by connecting devices utilizing low power, mid-range
wireless and wired communication technologies to the internet.
As a collection of protocols, cables and equipment in the middle to deliver signals and data
between objects, the virtual cable makes it easier to connect devices in LoryNet to establish
a new and desired network by improving reception from the distant or complicated
connections.
Accordingly, under the LoryNet Mode, uLory reads and writes entries, which are addresses
of a table to exchange data between devices with each table serving as an agency