User's Guide
tLory User Guide
21
109 1 Size R 0~0xff Size of changed entry
110 2 Reserved - - Reserved space
112 1
Usage rates of FIFO input
R 0~100 Usage rates of FIFO input (%)
113 1
Usage rates of FIFO output
R 0~100 Usage rates of FIFO input (%)
114 1 Over_Cnt R 0~255 Number of FIFO overrun
115 2 Tx Cnt, R 0~0xffff Number of rocket transmission
117 2 Rx Cnt, R 0~0xffff Number of rocket reception
119 1 Init R 1
Entries indicating the initialization of each
layer
Bit 0: Application layer
Bit 1: Table layer
Bit 2 : Route layer
Bit 4: Link layer
The bit 0 indicates that it is not initialized
while the bit 1 means the completion of
initialization. (The default value is 0x00
after the activation)
127 1 Ack R 1 Indicate the reception of Ack if it is not 0
128 1 Flag R 0~1
Value of temperature 1:Above zero,
0:below zero
129 1 Temperature R 0~0xff
Value of temperature of sensor(constant
value and Hex)
130 1 Temperature R 0~0xff
Value of temperature of sensor(decimal
value and Hex)
131 1 Humidity R 0~0xff
Value of humidity of sensor (constant value
and Hex)
132 1 Humidity R 0~0xff
Value of humidity of sensor (decimal value
and Hex)
133 1 LowBat R 0~1
Low Battery Flag
0:Normal, 1:Low Battery
134 122 Reserved