4.3 humidity
4.3.1 Relative Humidity
95%
4.3.2 Temperature
+55°C
4.3.3 Demands
No visual deterioration shall occur during the test. The antenna shall satisfy
the electrical demands, according to 2.4.1, after the test.
4.3.4 Measuring Method
The antenna is placed in a climatic chamber for 24 hours. The antenna is
taken out from the chamber and measured after another 24 hours in room
temperature.
4.4 Sinusoidal Vibration
4.4.1 Vibration Frequencies
10-55-10Hz (1cycle)
4.4.2 Sweep Rate
1 octave/min (logarithmic)
4.4.3 Maximum Amplitude
A = 1.52mm
4.4.4 Maxim Acceleration
2g
4.4.5 Crossover Frequency
18.2Hz
4.4.7 Measuring Method
The fixed antenna is assembled in the test equipment. The vibration is
done both in x-and z-directions, according to Figure 5(a), with a
duration of 1 hour in each direction.
(a) Vibration directions (b) Vibration form
Figure 5. Sinusoidal Vibrator