Overview
sCAN converts RS232 signals to CAN signals and CAN signals to RS232 signals. The built-in processor can
identify a serial command to modify the configuration or transmit/receive CAN signals. The CAN transmit/receive
commands can be modified that the users do not have to modify the software or the system they are using. The
commands can be sent to the unit by terminal, but for integrated use with others, sCAN utility is provided which
allows users to communicate, test and update the firmware.
Specification
CAN
Specification
CAN 2.0A and 2.0B
Maximum Distance
1km
Max. Speed
1Mbps
Connector
DE9 Plug
Signals
CAN_H, CAN_L, VDD, GND
EIA/TIA/
RS-232
Maximum Distance
15m
Max. Speed
460.8Kbps
Connector
DE9 Socket
Signals
TxD, RxD, GND, RTS, CTS, DTR, DSR
Hardware &
Environment
Power
5VDC (DE9 #9pin and/or CAN VBUS)
Dimension (W x L x H)
34.9 x 60.36 x 16.5mm
1.37 x 2.38 x 0.65in
Weight
50g (1.76oz)
Operating Temperature
-40 ~ 85 (-40 ~ 185)
Humidity
Max. 90% R.H
Software
OS
Windows XP/2003/Vista/2008/7/8/2012/10