User Manual

Eddy User's Guide
94
de.
S56: BD Address of Last Connected Device
This saves the Task4 BD address of the Bluetooth device connected most recently in a multiple connection mo
de.
S57: Slave Disconnect Timeout (default 3)
This S57 register value defines the time period in seconds that a master unit waits in case a slave unit does n
ot receive the data sent from the master. For this time period, the master unit will not send data to all slave u
nits if any slave unit does not receive the data. If the slave unit does not receive the data after this time period
elapses, the master unit will disconnect the connection with the problematic slave unit. The value should be gr
eater than 0 and smaller than the Supervision Timeout(S37).
S58: MAX TX POWER (default 0)
This value describes the peak output power. Setting this causes rebooting and applying. (There is
a little deviation according to the devices.)
Parameter
dBm
0
Use chip setting.
1
-12
2
-8
3
-4
4
0
5
4
6
8
7
12
8
16