User Manual

Eddy User's Guide
79
AT+UARTCONFIG,Baudrate,Parity,Stopbit,Hwfc
Response
OK
Purpose
Set Serial parameters
Parameter
s
Baudrate=1200/2400/4800/9600/14400/19200/38400/57600/115200/230400/460800/9
21600 (Default=9600)
Parity=N/E/O (Default=N)
Stopbit=1/2 (Default=1)
Hwfc(Hardware Flow Control)=0/1 (Default=1)
Descriptio
n
The Serial parameters can be set or changed. The factory default is 9600, N, 1, 1.
To take effect the ATZ command must be used or Powercycle the unit.
Example
AT+UARTCONFIF,115200,N,1,1
AT+BTINFO?
Response
112233445566,DeviceName,Mode,Status,Auth,Encryp,FlowControl
OK
Purpose
Display Bluetooth settings
Description
The current Bluetooth settings are displayed including BD address, Device name,
Operation mode, Operation status, Authentication, Data Encryption, and Hardware
Flow Control. The initial value of Device name is ESD100V2_v2.0.0-445566. ESD
stands for Eddy-BT, v2.0.0 for the version of firmware, and 445566 for the last 6 digits
of BD address.
Mode=MODE0/MODE1/MODE2/MODE3
Status=STANDBY/PENDING/CONNECT
Auth=0/1 (Authentication is not activated when 0)
Encrypt=0/1 (Encryption is not activated when 0)
FlowControl=HWFC/NoFC
AT+BTINQ?
Response
112233445566,FriendlyName,CoD
112233445566,FriendlyName,CoD
112233445566,FriendlyName,CoD
OK
Purpose
Search Bluetooth devices nearby
Description
The Bluetooth devices in Inquiry scan mode nearby are displayed with their BD
addresses, Device names, and Class of device.
Maximum 15 devices are scanned for 30 seconds. (Default 15 value in S-register 24)