CS-428.9AT-mini2_Quick User Manual
User's Manual
CS-428/9AT-mini2
User's Manual
CS-428/9AT-mini2
User's Manual
CS-428/9AT-mini2
➊
➋
➌
➍
➎
➏
1. Introduction
This product is manufactured under strict quality control, and comes
with 5 years limited warranty. The warranty comes in effect from
the date of purchase. If there are any difficulties or questions during
the use, please contact our Technical Support Department. http://
www.solvline.com
2. Function
■
This is a serial communication interface converter which converts
RS232 signals to RS422 or RS485 signals and extends the
distance up to maximum 1.2km. It also allows to be connected to
maximum 10 devices by multi-drop mode as well as point to point
mode.
■
It is designed to operate without external power supply.
(When RS232 side is extended, use external power supply
shown in page 4, “6. Power Supply”.) However, there is a socket
for an adapter to supply power externally.
■
It includes highly-effective surge protector to protect itself
from the transient voltage(Max. 15KV) coming along the
communication line.
■
Especially, CS-428/9AT includes an automatic opening and
closing function for the output data so that the opening and closing
consent work in the multi-drop mode is automatically made by
the hardware, which makes you apply easily under any installing
environment without any software operation.
3. Specifications
Model
CS-428/9AT-mini2 : DE9 Connector, automatic
opening-closing function termination resistor
Communication type Asynchronous serial communication
Transmission speed Maximum 921.6Kbps
Distance
Maximum 1.2Km
(Refer to chart-transmission distance per
transmission speed)
Connector
RS232 side : RS422/RS485 side
DE9 Female : Terminal Block
Dip Switch
RS422/485 Termination Resistor
RS485 Echo-Mode
Power
w/o External Power : RS232 TXD, RTS,
DTR signal
w/ External Power : Voltage: 9~12VDC
Polarity: Indepedent
Circuit protection 15KV-surge protector included.
Operating Temperature -40
℃
~ 85
℃
LED TXD(Green), RXD(Red), PWR(Red)
※
DCD.DSR and CTS are connected to GND internally
4. Structure
5. Connector
RS422
* DCD, CTS, DSR signal lines are not used.
4-wire RS422/485 2-wire RS485
* Polarity Independent Power
6. Power Supply
This unit operates by the power from TXD, RTS and DTR signal
generated from the computer or the RS232 port of the equipment when
no external power is supplied. When TXD, RTS and DTR signals
connected to the DE9 connector can not supply enough power, an
external power source is required. You can recognize whether the power
is being supplied or not, by cheking the power LED on the converter.
The power source part of the converter includes a high volume
condenser to supply stable power to the converter circuit by using TXD,
RTS and DTR signal. Therefore it may not work for a very short period
(within 0.1 second) until this condenser is filled with enough power.
Please wait for a second before starting to use converter after turning
on the TXD, RTS and DTR signal when TXD, RTS and DTR signal is
controlled directly in the application program.
The red LED light is turned on when power is supplied.
Supply an external power when power LED is off or dim.
7. Termination Resistor
When a communication error occurs due to high data rate or long cable
runs, enable the termination resistors to solve the problem.
■
Enabling Termination Resistor
* Termination resistor configuring are controlled by switches.
* Refer to '8. Operating Mode' to know how to set the switch.
8. Configuring Mode
This product allow user to select different operating modes to be
applied for various fields. Use the 4 dip switches on the bottom of
the product to set the desired operating modes before using.
■
Switch Configuration
After setting the switches, insert the line into the terminal block
and fix them with a screw driver. Connect the DE9 connector to
the RS232 port of the computer or serial device.
9. Configuration for RS422/485 4-wire
This connection is used for 1:1 (Point to Point) or 1:N (Multi-Drop)
full-duplex communication.(Max. 10 units)
■
Host and terminal configuring switch for the host and the terminal.
* When using RS422/485 4-wire interface, both point to
point and multi-drop mode are automatically supported.
* When using RS422 multi-drop mode, output signal line
does nothave to be opened and closed on the host side
since it is "dedicated" line. On the other hand for terminal
side, it always has to open and close the signal line when
it sends or receives communication data. This is done
automatically by hardware so the application program
does not have to control this.
■
Wire Connection
〈
Point to Point
〉
DIP SW OFF ON
1 RS422 OR 4-wire RS485 2-wire RS485
2
When using 2-wire RS485 mode
Non-Echo Mode Echo Mode
3
When using RS422/RS485 4-wire mode
Disable Termination Resistor Enable Termination Resistor
4
When using 2-wire RS485 mode
Disable Termination Resistor Enable Termination Resistor
RS232 to RS422/485 Converter
CS-428/9AT-mini2
www.sysbas.com
Serial Communication
Links the New World !
IoT Experts
16F Daerung Post Tower-1, 288, Digital-ro, Guro-gu, Seoul, Korea
Tel. +82-2-855-0501 Fax. +82-2-855-0580
www.sysbas.com / marketing@sysbas.com
2020.07.01
User’s Manual
Version 1.2
Industrial
Grade
IoT Experts
16F Daerung Post Tower-1, 288, Digital-ro, Guro-gu, Seoul, Korea
Tel. +82-2-855-0501 Fax. +82-2-855-0580
www.sysbas.com / marketing@sysbas.com
5-Year WarrantY
Help Hotline : +82-2-855-0501
E-Mail & Website : tech@sysbas.com / www.sysbas.com
Fax : +82-2-855-0580
SystemBase Co., Ltd. warrants that the Product(s) shell be free
from manufacturing defects in materials and workmanship for a
period of ve (5) years from the date of delivery provided that the
Product was properly installed and used. Defects, malfunctions
or failures of the warranted Product caused by damage resulting
from acts of God (such as oods, fre, etc.), environmental and
atmospheric disturbances, other external forces such as powerline
disturbances, host computer malfunction, plugging the board in
under power, or incorrect cabling and damage caused by misuse,
abuse and unauthorized alteration or repair are not warranted.
The warranty is limited to the repair and/or replacement, at
SystemBase’s option, of the defective Product during its warranty
period. Customer must obtain a Return Material Authorization (RMA)
number prior to returning the defective Product to SystemBase for
service. Customer agrees to insure the Product or assume the risk
of loss or damage in transit, to prepay shipping charges and to use
the original shipping container or equivalent. Contact SystemBase
Customer Support at tech@sysbas.com for further information.
Product repaired or replaced shall be warranted for the duration of
the initial Product warranty period, whichener is longer.
The warranty is limited to the repair and/or replacement, at
SystemBase’s option, of the defective Product during its warranty
period. Customer must obtain a Return Material Authorization (RMA)
number prior to returning the defective Product to SystemBase for
service. Customer agrees to insure the Prod