GENIOX VOCLEAN IOM

Contents
35Recommended Maintenance Interval
R.3. Autowash System
Region Interval Instructions
Water Pipes Of The
Autowash System
1-2
Weeks
Checks should be performed on regular intervals to make sure that the pipes used in the
Autowash system have not been dislodged and that there are no holes in pipes.
If the pipes have been dislodged, they should be xed in place and well tightened using
clamps. If there are holes in the pipes and there is a water leak, the pipes should be replaced
with identical ones or pipes with similar specications.
During winter, in cases where the washing function is disabled the water remaining in the
pipes may have frozen. In this case damage can occur to the system and the washing function
cannot be carried out.
In such cases the frozen water inside the pipe can be thawed by pouring warm water on pipes
or another process that will achieve the same end without damaging pipes can be applied.
Water pipes can be wrapped in insulation materials to prevent freezing.
Autowash System
Washing Group
1-2
Weeks
The washing group comprises nozzles and the metallic framework on which the ESP collectors
are mounted.
Checks should be performed on regular intervals to make sure there is no clogging in
nozzles (due to calcication, grease accumulation, etc. reasons) or any bending or breakage in
nozzles.
In case of clogging, the ends of nozzles should be wiped with a cloth moistened with a
mixture of water and detergent, and the section where the water is sprayed should be cleared
thoroughly using pressurized air if necessary.
Any impact that will occur on the nozzles during the removal and mounting of ESP collectors
can cause the nozzles to bend or break. In such a situation, you should contact the
manufacturer and request a new nozzle, and remove the old nozzle and install the new one in
its place.
ESP Pan of the
Autowash System
1-2
Months
These pans are manufactured of stainless steel material and are equipped with drainage pipes
manufactured of stainless steel material conforming to the DN32 standard.
Each of these drainage pipes should be connected to a single drainage pipe and the greasy
waste water should be passed through a degreaser.
Ball siphons or plugs should not be installed on the ends of drainage pipes.
Although the washing process will occur every night, oily residues can occur on the surfaces
of pans after a while. These residues should be thoroughly cleaned at specied periods, using
a cloth and mixture of water at 50-60°C and degreasing detergent.
WARNING
Before performing maintenance and cleaning tasks the power supply to the ecology unit must be cut off, and the cam switch or on/off
button on the panel of Autowash system panel should be switched to the off position.
Wait 60 seconds for any static electricity load to be dissipated.