GENIOX VOCLEAN IOM

10 Drawings, diagrams, guides and instructions for the use, maintenance and repair
E Drawings, diagrams, guides and instructions for the use, maintenance and repair
F Employees in charge of operation/control/maintenance
G Ecology unit in operation
H Instructions for unloading on the site as well as installation and connection
All units are manufactured in compliance with the EC Declaration of Conformity and they are CE marked as machines. If the buyer
carries out changes or adds components in or on the machine, the buyer must issue a new EC Declaration of Conformity and a new
CE marking of the machine.
To promote correct use of the machines, the below-mentioned instructions are an integral part of the machine:
Instructions for use of the machine
Instructions about adjustment and maintenance
Safety during adjustment and maintenance
Wiring diagram, if the unit is delivered with control system.
Operators Guide (also called Users Guide), if the unit is delivered with control system.
The units are constructed and built with a fully integrated control system. After start-up and hand-over from installer to operators/
users, the unit operates fully automatically.
Indications of operating status as well as indication of faults are visible in the display at the hand terminal. The operators/users can
enter new parameters in the controller via the hand terminal. Alternatively, the controller can be connected to a BMS system so
that new parameters can be selected via PC, tablet or Smartphone. The operators/users do not need to open inspections doors for
the operation.
Skilled technicians must carry care out maintenance as well as repairs.
Before start-up of the unit all ducts, safety guards and all protective devices must be mounted to prevent any access to rotating fan
impellers. All inspection doors must be closed and locked when the unit is in operation.
Donotusetheunitwithoutlters.
The Ecology Unit - is delivered as one section or in several sections, which are to be assembled on site. The Ecology unit is
delivered on transport pallets, legs, base frame with brackets for lifting or base frames with holes for forks on forklifts.
Loading and unloading as well as transport on the site is possible by fork-lift truck or by crane using suitable lifting straps.
Possible(✓)andnotpossible(X)handlingmethodsaredescribedinthetablebelow.
H.1 Unloading on the site
H.1.1 Handling methods
Type
Handling Methods
Forklift
Lifting by
straps
Brackets at
base frame for
lifting
Hoist holes in
base frames
Holes in base
frames for
forks (option)
Corners in
sections for
lifting
Sections on pallets X X X
Sections on base frames
Unit on base frame X
Table 2. Handling Methods