Press the sections hard together so that the rubber pro-
files are so flat that the iron frames of the two sections
are joined. Strap with tensioner is suitable for pressing
the sections hard together.. Note! To avoid any load and
stress on the vertical profiles the strap must be carefully
placed on the bottom profiles of the unit.
The sections must then be locked permanently together
with 8 mm bolts and nuts through the grey guiding and
connection blocks. Systemair has provided you with the 8
mm bolts with round heads and nuts required to carry this
task out. An Allen key size 6 mm will be required.
Note! Do not pull the sections together by tensioning
the 8 mm bolts. Use the strap for this purpose.
Assembly has been completed successfully.