Geniox user manual

Table Of Contents
44
| The essential characteristics of tools which may be fitted to the machinery
Cut-resistant gloves for protection against injury from sharp metal plate edges. Use CE-marked gloves for
this purpose.
Helmet.
Particulate respirator maintenance free including foam face-seal and adjustable pre-threaded
headbands for replacing filters.
Eye protection.
Ear protection.
Padlock for locking the automatic circuit breakers.
M The essential characteristics of tools which may be fitted to the machinery
The subject in the Machinery Directive about tools on the machine does not exist for the Geniox air handling units, be-
cause those tools does not exist.
N The conditions of stability during use, transportation, assembly, dismantling
when out of service
The unit must always be handled in an upright position. Never tilt any section more than 15 degrees. If sections must
be tilted more than 15 degrees, sections with fans or rotating exchangers that can be drawn out for service must be se-
cured carefully.
During transportation, installation, dismantling or other handling, it must be secured that all components in the unit are
properly fastened and with additional attention to the control of anti-vibration mounts under the fans that they are un-
damaged. The mounting and smooth running of the fans must be controlled and handled with great care.
N.1 Installed reliable to avoid units to be tilted or moved by storm
Units installed on roofs and other places with the risk of heavy winds must be installed reliable to avoid that they can
be tilted or moved by the any storm. The base frame is provided with holes that are intended for fastening by sufficient
bolts and fittings supplied by the installer.
N.2 Transport of section with heat pump unit
Warning
During transportation, the unit section Geniox HP must always be in the upright position or tilted less
than 30˚. If it is necessary to tilt the unit more than 30˚, the suction pipe of the compressor must point
upwards to prevent the escape of oil from the compressor sump.
N.3 Disposal of the heat pump system - type Geniox - HP
Prior to the disposal of the Geniox HP unit section, the refrigerant in the heat pump system must be drained off by a
skilled technician from a certified company. After correct evacuation of the refrigerant, the disposal of the Geniox HP
unit section is similar to the disposal of the rest of the air handling unit.
N.4 General disassembly sharp edges
Pay attention to several sharp edges during dismantling and disposal of the unit. To avoid injury, CE-marked cut-resist-
ant gloves as well as helmet must be used. The measures are described further in the Maintenance, Dismantling and
Disposal Manual.