Geniox user manual

Table Of Contents
Drawings, diagrams, guides and instructions for the use, maintenance and repair |
11
C.3 Hand terminal, if the unit is delivered with control system.
The hand terminal is delivered in a cardboard box containing the other external control components. This cardboard box
is usually, but not always, placed in the section with the supply air fan.
This is the NaviPad control panel for the Access control
system from Systemair.
The hand terminal is connected by a cable to the control-
ler in the cabinet. 3 meters of cable is delivered with the
unit and the customer has the possibility to replace this
cable with an identical type of cable that is up to 100 me-
ters long.
C.4 Dimensions of the units
See Annex 2 with information about the exact dimensions.
C.5 Ordinary automatically operation only manual operation by new parameters
The unit is operating fully automatically and manual operation includes only selection of new parameters via a hand ter-
minal. The alternative is that the controller is connected to a BMS system with the ability to select new parameters via
PC, tablet or SmartPhone.
D Drawings, diagrams, guides and instructions for the use, maintenance and
repair
All units are manufactured in compliance with the EC Declaration of Conformity and they are CE marked as machines.
Unique Declaration with production number of the machine is an integral part of the machine enclosed as Annex 1 to
this manual. If the buyer carries out changes or adds components in or on the machine, the buyer must issue a new EC
Declaration of Conformity and a new CE marking of the machine.
To promote correct use of the machines, the below-mentioned instructions are an integral part of the machine:
Unique drawings, data and description of functions for the delivered unit Annex 2
Instructions for use of the machine chapter J in this manual
Instructions about adjustment and maintenance chapter Q in this manual
Safety during adjustment and maintenance chapter R
Wiring diagram, if the unit is delivered with control system.
E Employees in charge of operation/control/maintenance
The units are constructed and built with a fully integrated control system. After start-up and hand-over from installer to
operators/users, the unit operates fully automatically.
Indications of operating status as well as indication of faults are visible in the display at the hand terminal. The opera-
tors/users can enter new parameters in the controller via the hand terminal. Alternatively, the controller can be con-
nected to a BMS system so that new parameters can be selected via PC, tablet or Smartphone. The operators/users do
not need to open inspections doors for the operation.
Skilled technicians must carry care out maintenance as well as repairs.
F Intended use and range of applications
The air handling units are intended for transport and treatment of air between -40 °C and + 40 °C The units are exclu-
sively for comfort ventilation. The units are not for environments that exceed the corrosion class C4 according to EN ISO
12944-2 (motors are constructed for handling of air between -20 °C and + 60 °C).