Speed control for rotor and assembly of divided rotor |
10-22
10.5.2.2 Block the rotor
Caution
The heat storage mass is very sensitive! Avoid high pressure, knocks, etc.
The already mounted rotor part needs to be blocked by a timber beam or by timber beams before installing the next
segment.
10.5.2.3 Assemble segments, circumferential panels and spacer discs
During the assembly of the segments, be sure to keep track of the numbering (segments are numbered in order, see
figure below.
Do not remove the square profiles (transport protection) until the segment ahead of it has been mounted.
The appropriate segment needs to be inserted through the mounting corner into the guide grooves of the preceding
segment. Screw the segment foot to the rotor hub using the M12x40 socket screws. Do not forget the retainers.
output | 11