HHFLEX E DECEMBER 2020

HHFlex air handling units
systemair 19
UNIT TYPES
SUPPLY UNIT
Heigth
Width
Length
Weigth
Heigth
Width
Length
Weigth
Heigth
Width
Length
Weigth
858
04.02 04.04 06.06
08.08 10.10 12.12 14.14 16.16 20.16 24.18
898 1,218 1,538 1,858 2,178 2,498 2,818 2,818 3,138
738 738 1,058 1,378 1,698 2,018 2,338 2,658 3,298 3,938
2,818 1,058 1,218 1,538 1,698 1,858 2,178 2,658 2,978 2,178
150 150 230 360 530 725 945 1,475 2,010 1,625
2,178 2,178 2,338 2,658 2,818 3,138 3,458 3,778 4,196 3,396
235 255 370 570 760 1,090 1,500 1,925 2,580 2,355
2,658 2,658 2,818 3,138 3,298 3,458 3,778 3,938 4,676 4,196
285 310 460 700 935 1,290 1,660 2,185 3,035 3,170
658 898 1,218 1,538 1,858 2,178 2,498 2,818 2,818 3,138
738 738 1,058 1,378 1,698 2,018 2,338 2,658 3,298 3,938
658 898 1,218 1,538 1,858 2,178 2,498 2,818 2,818 3,138
738 738 1,058 1,378 1,698 2,018 2,338 2,658 3,298 3,938
Table 8: Types of supply unit - dimensions and weights of the same types as the ‘Selection tables’ section.
WITHOUT COILS
WITH HEATING COIL
WITH HEATING AND COOLING COIL
UNIT TYPES
RUN AROUND COIL EXHAUST UNIT
Heigth
Width
Length
Weigth
858
04.02 04.04 06.06
08.08 10.10 12.12 14.14 16.16 20.16 24.18
898 1,218 1,538 1,858 2,178 2,498 2,818 2,818 3,138
738 738 1,058 1,378 1,698 2,018 2,338 2,658 3,298 3,938
2,178 2,178 2,338 2,658 2,818 2,978 3,618 3,938 4,356 3,556
245 270 410 625 860 1,195 1,760 2,260 2,965 2,955
Table 9: Types of run around coil exhaust unit - dimensions and weights of the same types as the ‘Selection tables’ section.
UNIT TYPES
RUN AROUND COIL SUPPLY UNIT
Heigth
Width
Length
Weigth
Heigth
Width
Length
Weigth
Heigth
Width
Length
Weigth
858
04.02 04.04 06.06
08.08 10.10 12.12 14.14 16.16 20.16 24.18
898 1,218 1,538 1,858 2,178 2,498 2,818 2,818 3,138
738 738 1,058 1,378 1,698 2,018 2,338 2,658 3,298 3,938
2,178 2,178 2,338 2,658 2,978 3,138 3,458 4,258 4,356 3,716
230 255 390 605 860 1,210 1,590 2,600 2,905 2,990
2,498 2,498 2,658 2,978 3,298 3,458 3,778 4,578 4,676 4,036
255 290 440 675 955 1,330 1,745 2,790 3,170 3,285
2,978 2,978 3,138 3,458 3,778 4,098 4,258 5,058 5,156 4,676
305 345 540 810 1,130 1,625 2,025 3,160 3,590 3,995
Table 10: Types of run around coil supply unit - dimensions and weights of the same types as the ‘Selection tables’ section.
WITH HEATING COIL
WITH HEATING AND COOLING COIL
858 898 1,218 1,538 1,858 2,178 2,498 2,818 2,818 3,138
738 738 1,058 1,378 1,698 2,018 2,338 2,658 3,298 3,938
858 898 1,218 1,538 1,858 2,178 2,498 2,818 2,818 3,138
738 738 1,058 1,378 1,698 2,018 2,338 2,658 3,298 3,938