EDM SYSCREW AIR EVO HSE
|
SYSCREW 380-1260 AIR EVO HSE
7
Accessories & Options (continued)
SYSCREW 380-1260 AIR EVO HSE Delivery Abbreviation Description & Benet
Stepless control Std ICC
Itallowstofollowcontinuouslycapacityloadmodicationswithout
having sensitive variation on water temperature. Thanks to the
control logic this effect can be obtained even combining a multi
stepxedscrewcompressorwithaninverterdrivencompressor.
Compressor box Std CB
Metal box enclosing screw compressor and offering sound reduc-
tion and protection from atmospheric agents.
Bacnet protocol kit for BMS (RS485) Option BAC
ItallowstheintegrationoftheunitwithBMSusingBacnetprotocol
through RS485 port.
Bacnet protocol kit for BMS (Ethernet) Option BAC/ETH
ItallowstheintegrationoftheunitwithBMSusingBacnetprotocol
throughEthernetport(TCP/IP).
Softstarter for compressor Option SS
An electronic device that automatically starts up the compressors
gradually. The starting current can be reduced by up to 40% of the
direct on line value.
Power factor corrector capacitors Option PFC
The purpose of the power factor corrector capacitor is to minimize
the input current distortion and make the current in phase with the
voltage.TargetistokeepPowerFactorabout0,90inanyrunning
condition.
Compressor Star Delta Start Option SD
Itallowstoreduceinrushcurrentvalueincasethedefaultcom-
pressor is using motor with Part Winding starting system.
Mechanical gauges kit (HP and LP manometers) Option KM
Pressure gauges that display the operating pressure in the high and
low pressure sections of the refrigerant circuit.
Compressor suction valve Option CSV
Mounted on the suction port of the compressor, it allows to insulate
the compressor from the suction refrigerant line for maintenance
purposes.
Brine Version Option BC
Special Version with dedicate devices on refrigeration system
allow the units to operate with brine (ethylenic or propylenic glycol)
down to -8°C.
Compressor oil switch Option OD
Itallowstochecktheproperlevelofoilinsidecompressorcarter
inordertoprotectfromlackoflubrication.Inverterdrivenscrew
compressor standard include this device.
E-coating MCHX Option E-COAT
Itisastronganti-corrosiontreatmentsuitabletoprotectMCHXcoils
from medium level of pollution and marine atmosphere.
Chiller grilles Option KG Grilles to protect unit avoiding possible intrusion into the unit.
Polar Version Option PC
Special version with Electronic fans and dedicate devices on
refrigeration system allow the units to operate at ambient
temperature down to -18°C.
Compressor acoustic box Option CAB
Compressor box is additional equipped with internal sound layers
offering further acoustic reduction. Standard supplied on S (Super
Low Noise) versions.
Total heat recovery Option TR
Additional exchanger in order to recover 100% of the rejected
heating capacity, suitable to produce hot water while the unit is
generating cooling effect.
Desuperheater Option D
Additional exchanger in order to recover a portion of the rejected
heating capacity, suitable to produce hot water while the unit is
generating cooling effect.
Remote On/Off control Accessory
Itenablestheoperatortopowerontheunitwhenitisinstandby
mode, to display alarms and switch over cooling–heat pump.
Maximumlength:50mt.
Remote keyboard panel Accessory
Makes it possible to control the unit through the remote
terminal, up to a maximum distance of 400 mt of telephone cable.
netTune Accessory
Itallowstopilotanetworkofupto6unitsoperatinginparallel,
managing load balance, unit rotation and stand-by operation.
Spring type AVM Accessory AVM
Multi-springantivibratingkit,sizedaccordingthedenedweight
distribution, providing insulation from vibration.
Flow switch Accessory FS
Preventstheoperationoftheunitifthecirculatingchilleduidis
insufcient.Itisrecommendedtoinstallaowswitchtoensurethe
correct operation of the unit.
Waterlter
Accessory
Filter to remove impurities from the water supply.
Accessoriesaresuppliedloosetobeinstalledoneld.Optionsarefactorymountedonboardoftheunit.