SYSHRW Engineering Data Manual (EDM HRW S 4GB)

SYSHRW
33
Entering Water
Temp (°C)
Water ow
(l/h)
Water Pressure
Drop (kPa)
Cooling mode
TEA (°C) Pt (W) Ps (W) Pabs (W) CR (W) EER
20
3924 61
24/17 17433 13370 3853 21286 4,52
27/19 18801 14258 3917 22718 4,80
30/21 20355 15080 3983 24338 5,11
2952 34
24/17 16888 13061 3937 20825 4,29
27/19 18535 14055 4066 22601 4,56
30/21 20175 15082 4163 24338 4,85
1944 15
24/17 16474 12853 4183 20657 3,94
27/19 18077 13959 4347 22424 4,16
30/21 19532 14735 4448 23980 4,39
27
3924 61
24/17 16336 12745 4521 20857 3,61
27/19 17683 13653 4652 22335 3,80
30/21 19063 14520 4729 23792 4,03
2952 34
24/17 15907 12647 4627 20534 3,44
27/19 17495 13638 4789 22284 3,65
30/21 18492 14439 4857 23349 3,81
1944 15
24/17 16057 12645 4962 21019 3,24
27/19 17233 13592 5087 22320 3,39
30/21 18388 14373 5203 23591 3,53
30
3924 61
24/17 15850 12602 4852 20702 3,27
27/19 17174 13536 4970 22144 3,46
30/21 18545 14473 5058 23603 3,67
2952 34
24/17 15994 12719 5026 21020 3,18
27/19 16851 13342 5121 21972 3,29
30/21 18298 14317 5226 23524 3,50
1944 15
24/17 15669 12471 5282 20951 2,97
27/19 16644 13215 5397 22041 3,08
30/21 17799 14010 5548 23347 3,21
32
3924 61
24/17 15929 12667 5111 21040 3,12
27/19 16716 13256 5181 21897 3,23
30/21 18217 14267 5306 23523 3,43
2952 34
24/17 15649 12458 5248 20897 2,98
27/19 16460 13228 5318 21778 3,10
30/21 17876 14057 5444 23320 3,28
1944 15
24/17 15257 12319 5498 20755 2,78
27/19 16228 13207 5620 21848 2,89
30/21 17417 14067 5774 23191 3,02
38
3924 61
24/17 14522 11952 5714 20236 2,54
27/19 15645 12833 5846 21491 2,68
30/21 16963 13775 6009 22972 2,82
2952 34
24/17 14805 12141 5934 20739 2,49
27/19 15552 12901 5987 21539 2,60
30/21 16705 13756 6154 22859 2,71
1944 15
24/17 14316 11937 6165 20481 2,32
27/19 15309 12876 6347 21656 2,41
30/21 16635 13717 6509 23144 2,56
40
3924 61
24/17 14615 12016 6029 20644 2,42
27/19 15257 12839 6087 21344 2,51
30/21 16523 13783 6252 22775 2,64
2952 34
24/17 14469 12040 6140 20609 2,36
27/19 15318 12882 6276 21594 2,44
30/21 16415 13717 6419 22834 2,56
1944 15
24/17 13729 11665 6344 20073 2,16
27/19 14731 12507 6490 21221 2,27
30/21 15932 13422 6715 22647 2,37
TEA : Entering air temperature (dry bulb/wet bulb).
Pt : Total cooling capacity.
Ps : Sensible cooling capacity.
Pabs : Compressor power input.
CR : Total heat rejection.
Cooling Performance Data - SYSHRW 072
Nominal airow 3570 m
3
/h