IOM SYSCW AR R513A (IOM CWAR 02 N 1GB/12.21)
Table Of Contents
- CONTENTS
- 1. GENERAL RECOMMENDATIONS
- 2. INSPECTION AND STORAGE
- 3. WARRANTY
- 4. TECHNICAL SUPPORT AND AFTER-SALES SERVICE HOTLINE
- 5. PRESENTATION
- 6. CONTENTS OF PACKAGE
- 7. DIMENSIONS
- 8. HANDLING
- 9. TECHNICAL SPECIFICATIONS
- 10. INSTALLATION
- 11. UNCLAMPING THE COMPRESSOR
- 12. HYDRAULIC LINKS
- 13. WIRING DIAGRAM AND LEGEND
- 14. ELECTRICAL CONNECTIONS
- 15. REGULATION
- 16. FINAL TASKS
- 17. STARTING - RECOMMENDATIONS - SETTINGS
- 18. MAINTENANCE
- 18.1. MAINTENANCE PROCEDURES
- 18.2. FAULT FINDING
- 18.2.1. NEITHER THE FAN NOR THE COMPRESSOR OPERATE
- 18.2.2. VENTILATION (FAN) MODE OPERATES BUT THE COMPRESSOR DOES NOT OPERATE
- 18.2.3. INSUFFICIENT COOLING OR HEATING PRODUCTION
- 18.2.4. INSUFFICIENT WATER FLOW AT THE LEVEL OF THE COAXIAL EXCHANGER.
- 18.2.5. APPEARANCE OF WATER DROPLETS IN THE APPLIANCE
- 18.2.6. APPEARANCE OF ABNORMAL NOISES AND VIBRATIONS IN THE CASING
- 18.3. ALARM CODES
- 19. WARRANTY CLAIM - MATERIAL RETURN PROCEDURE
- 20. ORDERING SERVICE AND SPARE PARTS ORDER
- 21. DISPOSAL
- DIMENSIONS
- SYSCW-AR R513A VC BA
- SYSCW-AR R513A VN BA
- SYSCW-AR R513A VC FA
- SYSCW-AR R513A VN FA
- SYSCW-AR R513A VCL BA
- SYSCW-AR R513A VNL BA
- SYSCW-AR R513A VCL FA
- SYSCW-AR R513A VNL FA
- HYDRAULIC CONNECTIONS
- SYSCW-AR R513A VC BA / SYSCW-AR R513A VN BA
- SYSCW-AR R513A VC FA / SYSCW-AR R513A VN FA
- SYSCW-AR R513A VCL BA / SYSCW-AR R513A VNL BA
- SYSCW-AR R513A VCL FA / SYSCW-AR R513A VNL FA
- REFRIGERANT CIRCUIT DIAGRAM
- WIRING DIAGRAM
- DIMENSIONS
- SYSCW-AR R513A VC BA
- SYSCW-AR R513A VN BA
- SYSCW-AR R513A VC FA
- SYSCW-AR R513A VN FA
- SYSCW-AR R513A VCL BA
- SYSCW-AR R513A VNL BA
- SYSCW-AR R513A VCL FA
- SYSCW-AR R513A VNL FA
- RACCORDEMENT HYDRAULIQUE
- SYSCW-AR R513A VC BA / SYSCW-AR R513A VN BA
- SYSCW-AR R513A VC FA / SYSCW-AR R513A VN FA
- SYSCW-AR R513A VCL BA / SYSCW-AR R513A VNL BA
- SYSCW-AR R513A VCL FA / SYSCW-AR R513A VNL FA
- SCHEMA DU CIRCUIT FRIGORIFIQUE
- SCHEMAS ELECTRIQUES
- ABMESSUNGEN
- SYSCW-AR R513A VC BA
- SYSCW-AR R513A VN BA
- SYSCW-AR R513A VC FA
- SYSCW-AR R513A VN FA
- SYSCW-AR R513A VCL BA
- SYSCW-AR R513A VNL BA
- SYSCW-AR R513A VCL FA
- SYSCW-AR R513A VNL FA
- HYDRAULIKANSCHLÜSSE
- SYSCW-AR R513A VC BA / SYSCW-AR R513A VN BA
- SYSCW-AR R513A VC FA / SYSCW-AR R513A VN FA
- SYSCW-AR R513A VCL BA / SYSCW-AR R513A VNL BA
- SYSCW-AR R513A VCL FA / SYSCW-AR R513A VNL FA
- KÄLTEKREISLAUFDIAGRAMM
- STROMLAUFPLANS
- DIMENSIONI
- SYSCW-AR R513A VC BA
- SYSCW-AR R513A VN BA
- SYSCW-AR R513A VC FA
- SYSCW-AR R513A VN FA
- SYSCW-AR R513A VCL BA
- SYSCW-AR R513A VNL BA
- SYSCW-AR R513A VCL FA
- SYSCW-AR R513A VNL FA
- COLLEGAMENTI IDRAULICI
- SYSCW-AR R513A VC BA / SYSCW-AR R513A VN BA
- SYSCW-AR R513A VC FA / SYSCW-AR R513A VN FA
- SYSCW-AR R513A VCL BA / SYSCW-AR R513A VNL BA
- SYSCW-AR R513A VCL FA / SYSCW-AR R513A VNL FA
- SCHEMA DEL CIRCUITO REFRIGERANTE
- SCHEMA ELETRICO
- DIMENSIONES
- SYSCW-AR R513A VC BA
- SYSCW-AR R513A VN BA
- SYSCW-AR R513A VC FA
- SYSCW-AR R513A VN FA
- SYSCW-AR R513A VCL BA
- SYSCW-AR R513A VNL BA
- SYSCW-AR R513A VCL FA
- SYSCW-AR R513A VNL FA
- CONEXIONES HIDRÁULICAS
- SYSCW-AR R513A VC BA / SYSCW-AR R513A VN BA
- SYSCW-AR R513A VC FA / SYSCW-AR R513A VN FA
- SYSCW-AR R513A VCL BA / SYSCW-AR R513A VNL BA
- SYSCW-AR R513A VCL FA / SYSCW-AR R513A VNL FA
- ESQUEMA DEL CIRCUITO FRIGORIFÍCO
- ESQUEMA ELECTRICO
English
4 SYSCW-AR R513A
1.3. EQUIPMENT SAFETY DATA
Safety data R513A
Toxicity level Low.
In contact with the skin
Dermal contact with the rapidly evaporating liquid can cause frostbite to the tissue. In the event
of contact with the liquid, warm the frozen tissue with water and notify a physician. Remove
contaminated clothing and shoes. Wash clothes before reuse
In case of eye contact
Steam has no effect. Splashing or splashing liquid can cause burns. Clean immediately with eye drops
or clean water for at least 15 minutes. Seek medical attention urgently.
Ingestion
Burns can occur if this happens. Do not induce vomiting. When the patient is conscious, wash the
mouth with water. Seek medical attention urgently.
Inhalation
If inhaled, move to fresh air and give oxygen if necessary. Perform artificial respiration if the patient
is no longer breathing or is short of air. In the event of cardiac arrest, perform external CPR. Seek
immediate medical attention.
Other medical advice
Cardiac sensitivity may, in the presence of circulating catecholamines such as adrenaline, lead to
increased arrhythmias and subsequent cardiac arrest if exposed to high concentrations.
Occupational exposure limits R513A: Recommended limit: 1,000 ppm - 8 hours.
Stability Room temperature stable product
Conditions to avoid
Pressure build-up due to high temperatures can cause the container to explode. Protect from sunlight
and do not expose to a temperature >50°C.
Dangerous reactions Possibility of dangerous reactions in case of fire due to the presence of F and/or CI radicals
General precautions
Avoid inhaling high concentrations of vapors. Atmospheric concentrations should be minimized
and kept as far as possible below the occupational exposure limit. Steam is heavier than air and
concentrates at a low level and in small places. Exhaust ventilation at the lowest levels.
Respiratory protection
If there is any doubt about the air concentration, breathing apparatus approved by the health services
should be used. These devices will contain oxygen or allow better breathing.
Storage
The containers must be placed in a dry and cold place away from any risk of fire, direct sunlight and
away from any heat source such as radiators. Temperatures should not exceed 50°C.
Protective clothing Wear coveralls, impermeable gloves and goggles or a face shield.
Procedure in case of spillage or
a leak
Make sure that everyone wears the appropriate protective clothing and respirators. If possible isolate
the source of the leak. Encourage evaporation of small spills provided there is adequate ventilation.
Large spills: ventilate the area. Contain spill with sand, earth or other suitable absorbent material.
Prevent liquid from entering drains, sewers, basements and manholes as the vapor can create a
suffocating atmosphere.
Waste disposal
Preferably to be recovered and recycled. If this is not possible, ensure that they are destroyed in an
authorized area able to absorb and neutralize acids and other toxic manufacturing products.
Fire fighting data R513A: Non-flammable at ambient temperatures and atmospheric pressures.
Containers
Containers exposed to fire must be kept cold by means of water jets. Containers may burst if
overheated.
Fire protection equipment In case of fire, wear self-contained breathing apparatus and protective clothing.