IOM SYSCW AR R513A (IOM CWAR 02 N 1GB/12.21)
Table Of Contents
- CONTENTS
- 1. GENERAL RECOMMENDATIONS
- 2. INSPECTION AND STORAGE
- 3. WARRANTY
- 4. TECHNICAL SUPPORT AND AFTER-SALES SERVICE HOTLINE
- 5. PRESENTATION
- 6. CONTENTS OF PACKAGE
- 7. DIMENSIONS
- 8. HANDLING
- 9. TECHNICAL SPECIFICATIONS
- 10. INSTALLATION
- 11. UNCLAMPING THE COMPRESSOR
- 12. HYDRAULIC LINKS
- 13. WIRING DIAGRAM AND LEGEND
- 14. ELECTRICAL CONNECTIONS
- 15. REGULATION
- 16. FINAL TASKS
- 17. STARTING - RECOMMENDATIONS - SETTINGS
- 18. MAINTENANCE
- 18.1. MAINTENANCE PROCEDURES
- 18.2. FAULT FINDING
- 18.2.1. NEITHER THE FAN NOR THE COMPRESSOR OPERATE
- 18.2.2. VENTILATION (FAN) MODE OPERATES BUT THE COMPRESSOR DOES NOT OPERATE
- 18.2.3. INSUFFICIENT COOLING OR HEATING PRODUCTION
- 18.2.4. INSUFFICIENT WATER FLOW AT THE LEVEL OF THE COAXIAL EXCHANGER.
- 18.2.5. APPEARANCE OF WATER DROPLETS IN THE APPLIANCE
- 18.2.6. APPEARANCE OF ABNORMAL NOISES AND VIBRATIONS IN THE CASING
- 18.3. ALARM CODES
- 19. WARRANTY CLAIM - MATERIAL RETURN PROCEDURE
- 20. ORDERING SERVICE AND SPARE PARTS ORDER
- 21. DISPOSAL
- DIMENSIONS
- SYSCW-AR R513A VC BA
- SYSCW-AR R513A VN BA
- SYSCW-AR R513A VC FA
- SYSCW-AR R513A VN FA
- SYSCW-AR R513A VCL BA
- SYSCW-AR R513A VNL BA
- SYSCW-AR R513A VCL FA
- SYSCW-AR R513A VNL FA
- HYDRAULIC CONNECTIONS
- SYSCW-AR R513A VC BA / SYSCW-AR R513A VN BA
- SYSCW-AR R513A VC FA / SYSCW-AR R513A VN FA
- SYSCW-AR R513A VCL BA / SYSCW-AR R513A VNL BA
- SYSCW-AR R513A VCL FA / SYSCW-AR R513A VNL FA
- REFRIGERANT CIRCUIT DIAGRAM
- WIRING DIAGRAM
- DIMENSIONS
- SYSCW-AR R513A VC BA
- SYSCW-AR R513A VN BA
- SYSCW-AR R513A VC FA
- SYSCW-AR R513A VN FA
- SYSCW-AR R513A VCL BA
- SYSCW-AR R513A VNL BA
- SYSCW-AR R513A VCL FA
- SYSCW-AR R513A VNL FA
- RACCORDEMENT HYDRAULIQUE
- SYSCW-AR R513A VC BA / SYSCW-AR R513A VN BA
- SYSCW-AR R513A VC FA / SYSCW-AR R513A VN FA
- SYSCW-AR R513A VCL BA / SYSCW-AR R513A VNL BA
- SYSCW-AR R513A VCL FA / SYSCW-AR R513A VNL FA
- SCHEMA DU CIRCUIT FRIGORIFIQUE
- SCHEMAS ELECTRIQUES
- ABMESSUNGEN
- SYSCW-AR R513A VC BA
- SYSCW-AR R513A VN BA
- SYSCW-AR R513A VC FA
- SYSCW-AR R513A VN FA
- SYSCW-AR R513A VCL BA
- SYSCW-AR R513A VNL BA
- SYSCW-AR R513A VCL FA
- SYSCW-AR R513A VNL FA
- HYDRAULIKANSCHLÜSSE
- SYSCW-AR R513A VC BA / SYSCW-AR R513A VN BA
- SYSCW-AR R513A VC FA / SYSCW-AR R513A VN FA
- SYSCW-AR R513A VCL BA / SYSCW-AR R513A VNL BA
- SYSCW-AR R513A VCL FA / SYSCW-AR R513A VNL FA
- KÄLTEKREISLAUFDIAGRAMM
- STROMLAUFPLANS
- DIMENSIONI
- SYSCW-AR R513A VC BA
- SYSCW-AR R513A VN BA
- SYSCW-AR R513A VC FA
- SYSCW-AR R513A VN FA
- SYSCW-AR R513A VCL BA
- SYSCW-AR R513A VNL BA
- SYSCW-AR R513A VCL FA
- SYSCW-AR R513A VNL FA
- COLLEGAMENTI IDRAULICI
- SYSCW-AR R513A VC BA / SYSCW-AR R513A VN BA
- SYSCW-AR R513A VC FA / SYSCW-AR R513A VN FA
- SYSCW-AR R513A VCL BA / SYSCW-AR R513A VNL BA
- SYSCW-AR R513A VCL FA / SYSCW-AR R513A VNL FA
- SCHEMA DEL CIRCUITO REFRIGERANTE
- SCHEMA ELETRICO
- DIMENSIONES
- SYSCW-AR R513A VC BA
- SYSCW-AR R513A VN BA
- SYSCW-AR R513A VC FA
- SYSCW-AR R513A VN FA
- SYSCW-AR R513A VCL BA
- SYSCW-AR R513A VNL BA
- SYSCW-AR R513A VCL FA
- SYSCW-AR R513A VNL FA
- CONEXIONES HIDRÁULICAS
- SYSCW-AR R513A VC BA / SYSCW-AR R513A VN BA
- SYSCW-AR R513A VC FA / SYSCW-AR R513A VN FA
- SYSCW-AR R513A VCL BA / SYSCW-AR R513A VNL BA
- SYSCW-AR R513A VCL FA / SYSCW-AR R513A VNL FA
- ESQUEMA DEL CIRCUITO FRIGORIFÍCO
- ESQUEMA ELECTRICO
English
26 SYSCW-AR R513A
Place the plugs back on the valves and check that they are properly tightened.
If needed, x the cables and the pipes on the wall with clamping collars.
Operate the SYSCW-AR in the presence of the user and explain all functions.
Show him how to remove, clean and place back the lters.
16. FINAL TASKS
17. STARTING - RECOMMENDATIONS - SETTINGS
1. Check that all the water valves are open and that water circulates in the appliance before making
any demand for heating or cooling.
2. Ensure that the units are connected correctly to the mains power supply (Refer to the § ELECTRIC
SPECIFICATIONS, page 9 and in § WIRING DIAGRAM, page XV).
3. Check that all of the appliance’s electrical connections have been tightened
4. Before attempting any start-up, ensure that the air and water temperatures are within the
appliance’s operating limits (in § OPERATING LIMITS, page 10).
5. Rotate the fan by hand to ensure that it turns freely and that the fan turbine is properly attached
to the motor shaft.
6. Check that the condensates drainage pipe is properly attached and free of any blockages.
7. Check the correct positioning of the lters and that they a clean and accessible.
8. Ensure that the nned heat exchanger surfaces are clean. Clean if required.
9. Check that the connection hoses are correctly tted and ensure that the appliance’s water circuit
has been correctly bled of any air.
10. Ensure that no Alarm code is displayed when the mains power supply is switched on (Refer to the
§ ALARM CODES, page 31).
11. Carry out the usual checks on the main water loop and particularly to ensure that the water
circulation pump operates correctly.
Non-compliance with this rule may result in irreversible damage. In addition, we recommend
the use of a ow controller on the units’ inlet pipe (not supplied).
Caution
Before the rst start-up the compressor transport clamping be removed. Failure to do this could
result in vibrations, high noise and could lead to the refrigerant tubes breaking.
Caution