Manual
Table Of Contents
- VLT® HVAC Basic Drive FC 101
- English US
- Contents
- Introduction
- Safety
- Installation
- Mechanical Installation
- Electrical Installation
- Electrical Installation in General
- IT Mains
- Mains and Motor Connection
- Introduction
- Connecting to Mains and Motor
- Relays and Terminals on Enclosure Sizes H1–H5
- Relays and Terminals on Enclosure Size H6
- Relays and Terminals on Enclosure Size H7
- Relays and Terminals on Enclosure Size H8
- Connecting to Mains and Motor for Enclosure Size H9
- Relays and Terminals on Enclosure Size H10
- Enclosure Size I2
- Enclosure Size I3
- Enclosure Size I4
- IP54 Enclosure Sizes I2, I3, I4
- Enclosure size I6
- Enclosure size I7, I8
- Fuses and Circuit Breakers
- EMC-correct Electrical Installation
- Control Terminals
- Electrical Wiring
- Acoustic Noise or Vibration
- Programming
- Warnings and Alarms
- Specifications
- Index
- English US
5 The triangle indicates if the LCP is in Status, Quick Menu, or Main Menu.
B. Menu key
Press [Menu] to select among Status, Quick Menu, or Main Menu.
C. Navigation keys and indicator lights
Table 14: Legend to Section C
6 Com. LED: Flashes during bus communication.
7 Green LED/On: Control section is working correctly.
8 Yellow LED/Warn.: Indicates a warning.
9 Flashing Red LED/Alarm: Indicates an alarm.
10 [Back]: For moving to the previous step or layer in the navigation structure.
11 [▵] [▿] [▹]: For navigating among parameter groups and parameters, and within parameters. They can also be used for setting
local reference.
12 [OK]: For selecting a parameter and for accepting changes to parameter settings.
D. Operation keys and indicator lights
Table 15: Legend to Section D
13 [Hand On]: Starts the motor and enables control of the drive via the LCP.
NOTICE
[2] Coast inverse
is the default option for
parameter 5-12 Terminal 27 Digital Input
. If there is no 24 V supply to
terminal 27, [Hand On] does not start the motor. Connect terminal 12 to terminal 27.
14 [Off/Reset]: Stops the motor (Off). If in alarm mode, the alarm is reset.
15 [Auto On]: The drive is controlled either via control terminals or serial communication.
4.2 Setup Wizard
4.2.1 Setup Wizard Introduction
The built-in wizard menu guides the installer through the setup of the drive in a clear and structured manner for open-loop and closed-
loop applications, and for quick motor settings.
Programming
Operating Guide | VLT® HVAC Basic Drive FC 101
AQ275641848264en-000101 / 132R0078
40 | Danfoss A/S © 2019.11