DELTRI+ POWERED BY BROCHURE2021 08 31
  systemair  7
Will DELTRI+ allow us to reactivate recirculation functions in our AHUs?
How long does a DELTRI+ lter last? 
Third-party tests at LIST have shown that the lters 
should last over a commonly recommended lter life cycle 
prescribed by trusted manufacturers suitable for your  
type of application and environment, but not longer than 
one year. We generally recommend shorter replacement  
cycles – independent from the lter solution.
Is this lter effective against COVID19?
Does this solution support us in tackling the potential impact of  
leakages in heat exchangers?
In many COVID19 recommendations, including Systemair’s, 
it is recommended to turn off recirculation functions in 
AHUs and switch to 100% fresh air supply mode. 
Recirculation was utilised in many situations before the 
pandemic to save energy (e.g., during a low occupancy at 
night in a building or when CO2 levels in a room are low). 
In an intelligent ventilation system, this was “normal” and 
made sense. 
Many building operators and owners have contacted 
us over the past months as they would like to activate 
recirculation functions again. First, however, they would 
like to have the condence to do so.
DELTRI+ is a straightforward solution in this respect. 
While high-quality ePM1 lters already help, the DELTRI+ 
technology offers an additional safety net, which can 
enable (partial) recirculation again to save energy.
As tested by the Luxembourg Institute of Science and 
Technology, DELTRI+ Technology signicantly reduces 
biological aerosols including SARS-CoV-2. However,  
the technology’s reliability ultimately depends on  
how well you generally maintain your units. It is also 
not a substitute for recommended COVID19 prevention 
measures in your markets, such as wearing masks, 
increasing ventilation rates, and the like.
As conrmed by respected organisations such as ASHRAE or 
REHVA, an inevitable leakage occurs with rotary and plate 
heat exchangers. However, in well maintained, designed 
and operated air handling units by trusted manufacturers, 
leakage impacts tend to be minimal. Furthermore, in 
rotors, purge sectors can further minimise leakages. 
To date, there is no scientic evidence that SARS-CoV-2  
can reach an air handling unit. However, if this was to occur, 
quality ltration is vital. DELTRI+ can play an important 
role here. It goes beyond the commonly recommended 
ISO16890 rated ePM1 lters by providing an additional 
layer of security and thus peace of mind for your clients.