F 4st
Screws M6 x 8.8
H 1st
Screw 4.2×32
L 1st
Plug 5.5×35
J 1st
Full seal damper
Fig. 2
Marking out the ceiling before
installation
Attention!
Max total height, distance between the
lower edge of the cooker hood and the
chimney's upper edge, see measure-
ments Fig. 1. When installing with an ex-
tended upper chimney part, see
dimensions for this.
Fig. 3
Protect the stove top with a piece of card-
board from the packaging, Fig. 3. Place the
cooker hood on the stove top. Make sure it
is flat with the filter resting on the surface.
Attention!
To avoid the risk of head injury, do not
allow any part of the product to protrude
beyond the front of the stove top.
Use a plumb line to mark the centre of the
cooker hood on the ceiling. Locate the cen-
tre of the drill template supplied, A Fig. 3,
against the marking in the ceiling so that
the cooker hood ends up in the intended
position.
Attention!
Turn the drill template so that the arrow
points in the same direction as the front
of the cooker hood.
Mark out the template screw holes, A, and
the connection to the outlet air duct. Drill
holes in the centre of all the marked screw
holes. Check which of the fastening alterna-
tives apply and adapt the holes to fit
screws/plugs or nuts, bolts and washers. If
the supplied plugs are to be used, drill 6
mm holes. Insert wall plugs D into the hol-
es. Check that the screws and plugs used
are intended for the ceiling material. Cut
out holes for connecting outlet air. Insert
and tighten screws C into the pre-drilled
holes for the keyhole attachments until
they protrude a few mm,Fig. 5 .
Check that the duct connection and electri-
cal connection can still be made once po-
wer is installed in the ceiling.
991.0433.864/126183/2016-02-08 23