SAVE VTC 700 INSTALLATIONV01

6
| Installation
5.2 Outdoor Air Intake Location Recommendation
Recommended installation location for the outdoor air intake is the northern or eastern side of the building and with a
distance to openings for discharge of stale ventilation air, kitchen ventilator, central vacuum system, waste water drain-
age and other pollution sources like exhaust from traffic, etc. Exhaust air should ideally be led via a roof cowl to the out-
side and with a good distance from the outdoor air intake, windows, etc.
5.3 Access to Power supply
The SAVE VTC 700 is supplied with approximately 1,5 m cable and plug for 230V, single phase earthed connection.
Make sure a power outlet is reachable by the plug.
6 Installation
Important
The device may only be installed by qualified, instructed and trained personnel. The persons must know the
relevant safety directives in order to recognise and to avoid risks.
C
B
A
D
Fig. 5 Installation position (right hand unit)
The unit must be installed in the following position (figure 5). It is important
that the unit is completely level in order for the condensation drainage to
work properly.
6.1 Installation procedure SAVE VTC 700
1 Prepare the surface where the unit will be mounted. Make sure that the
surface is flat, levelled and that it supports the weight of the unit. Perform
the installation in accordance with local rules and regulations.
2 Place the unit standing on the floor. Use the enclosed adjustable feet to
level the unit
Warning
Beware of sharp edges during mounting and maintenance.
Use protective gloves
254492 | v01