| Prerequisites for Installation
4.2 Delivery/Unloading
The appliance is delivered in one piece containing all necessary components, wrapped in plastic on a pallet for easy
transportation.
Checking delivery
• Check the packaging and the air handling unit for transport damage. Any findings should be noted on the cargo
manifest.
• Check completeness of the delivery.
Verify that all ordered equipment is delivered before starting the installation. Any discrepancies from the ordered
equipment must be reported to the supplier of Systemair products.
Warning
When opening the transport packaging, there is a risk of damage from sharp edges, nails, staples, splinters
etc.
Unpacking
• Check the air handling unit for visible transport damage.
• Only remove the packaging shortly before assembly.
• Beware of sharp edges during mounting and maintenance. Use protective gloves.
5 Prerequisites for Installation
To ensure a proper and fail-free operation, it is important that the unit is installed according to these instructions.
5.1 Location and Space Requirements
The SAVE VTC 500 should preferably be installed in a separate room (e.g. storeroom, laundry room or similar.).
When choosing the location it should be kept in mind that the unit requires maintenance regularly and that the inspec-
tion door should be easily accessible. Leave free space for opening the door and for taking out the main components
(figure 2).
5.2 Wall preparation for mounting bracket
The unit should be installed in such a way that there is no vibration noise
coming from the wall on which the unit is installed.
5.3 Outdoor Air Intake Location Recommendation
Recommended installation location for the outdoor air intake is the northern or eastern side of the building and with a
distance to openings for discharge of stale ventilation air, kitchen ventilator, central vacuum system, waste water drain-
age and other pollution sources like exhaust from traffic, etc. Exhaust air should ideally be led via a roof cowl to the out-
side and with a good distance from the outdoor air intake, windows, etc.
5.4 Access to Power supply
The SAVE VTC 500 is supplied with approximately 1,5 m cable and plug for 230V, single phase earthed connection.
Make sure a power outlet is reachable by the plug.
254488 | v01