SAVE VTR 700 INSTALLATIONV1 20210507 101120855

Installation |
7
5.1 Location and Space Requirements
The SAVE VTR 700 should preferably be installed in a separate room (e.g. storeroom, laundry room or similar.).
When choosing the location it should be kept in mind that the unit requires maintenance regularly and that the inspec-
tion door should be easily accessible. Leave free space for opening the door and for taking out the main components
(figure 4).
5.1.1 Required space
In order to be able to remove filters (figure 4) the unit needs to be installed with sufficient space in front as described
below.
Fig. 4 Space required
A 1580 mm
5.2 Condensation drainage
In general no condensation drainage is needed for rotational heat exchangers at dry conditions. However, if a lot of hu-
mid air is present in the residence, a condensation drainage might be needed. Drainage connection is available as an ac-
cessory and can be ordered separately. Installation instructions for the drainage are enclosed in the drainage pipes
delivery.
Note:
The drainage connection is plugged in the bottom of the unit at delivery. To use the drainage: remove the
rubber seal and connect the drainage pipe. Connect the drainage pipe to the sewer. The water can not be
led straight to the sewer without a water trap.
5.3 Outdoor Air Intake Location Recommendation
Recommended installation location for the outdoor air intake is the northern or eastern side of the building and with a
distance to openings for discharge of stale ventilation air, kitchen ventilator, central vacuum system, waste water drain-
age and other pollution sources like exhaust from traffic, etc. Exhaust air should ideally be led via a roof cowl to the out-
side and with a good distance from the outdoor air intake, windows, etc.
5.4 Access to Power supply
The SAVE VTR 700 is supplied with approximately 2 mcable and plug for 230V, single phase earthed connection.
Make sure a power outlet is reachable by the plug.
6 Installation
Important
The device may only be installed by qualified, instructed and trained personnel. The persons must know the
relevant safety directives in order to recognise and to avoid risks.
254524 | v01