SAVE VTR 100B INSTALLATIONV1

Table Of Contents
6
| Prerequisites for Installation
5.1 Location and Space Requirements
The SAVE VTR 100/B is to be mounted above a stove.
Continue to follow instructions how to find the correct height and depth for mounting bracket installation.
Fig. 4 SAVE VTR 100/B in a kitchen environment
MONOLIT-B
251-10/B 392–10/B
A
Minimum distance between cabinets (mm)
600 600 600
B
SAVE VTR 100/B unit width (mm)
561 561 561
C, Electrical stove Minimum distance between stove surface and
cooker hood (mm)
450
(Recommen-
ded 500)
450
(Recommen-
ded 500)
450
(Recommen-
ded 500)
C, Gas stove
Minimum distance between stove surface and
cooker hood (mm)
650 650 650
D
When flexible duct is used, distance between
the unit and cooker hood is decided by the
installer (minimum 100 mm).
100 100 10
E
The cooker hood height (mm)
130 150 97
F
Total height of the unit with cooker hood
connected by minimum 100 mm flexible duct
distance (D)
830 850 707
G
Distance to the mounting bracket from the
underside of the cooker hood or underside of
the cupboard if it is aligned with the cooker
hood (mm)
Note:
This distance must be increased
according to the increased measurement
D if flexible duct is used.
795 815 670
Important!
The unit requires regular maintenance and therefore kitchen furniture panel between cabinets where the unit is lo-
cated must be removable.
Depending on the cupboard depth and selected kitchen furniture panel installation method, the SAVE VTR 100/B unit
may have to me shifted forward using wood blocks at the back.